IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,754

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK1098 # 02 Y:2023 02 2023 REPLACE BOILER $2,974 $78,000 Implemented
OK1098 # 03 Y:2023 03 2023 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $75 $100 Implemented
OK1099 # 01 Y:2023 01 2023 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,723 $5,897 Not Implemented
OK1099 # 02 Y:2023 02 2023 AIR CONDITION ONLY SPACE NECESSARY $865 $0 Not Implemented
OK1099 # 03 Y:2023 03 2023 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $577 $416 Not Implemented
OK1099 # 04 Y:2023 04 2023 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT $160 $510 Implemented
OK1097 # 01 Y:2023 01 2023 USE EXISTING DAM TO GENERATE ELECTRICITY $9,070 $42,900 Not Implemented
OK1097 # 02 Y:2023 02 2023 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,461 $2,074 Not Implemented
OK1097 # 03 Y:2023 03 2023 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $310 $291 Implemented
OK1097 # 04 Y:2023 04 2023 USE SOLAR HEAT TO MAKE ELECTRICTY $19,348 $189,810 Not Implemented
OK1092 # 01 Y:2023 01 2023 USE RADIANT HEATER FOR SPOT HEATING $21,822 $92,250 Not Implemented
OK1092 # 02 Y:2023 02 2023 USE PHOTOCELL CONTROLS $131 $370 Not Implemented
OK1092 # 03 Y:2023 03 2023 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,058 $2,490 Not Implemented
OK1092 # 04 Y:2023 04 2023 USE SOLAR HEAT TO MAKE ELECTRICTY $24,882 $187,200 Not Implemented
OK1091 # 01 Y:2023 01 2023 INSTALL OCCUPANCY SENSORS $1,017 $630 Implemented
OK1091 # 02 Y:2023 02 2023 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $3,533 $9,900 Implemented
OK1091 # 03 Y:2023 03 2023 AIR CONDITION ONLY SPACE NECESSARY $17,766 $0 Not Implemented
OK1091 # 04 Y:2023 04 2023 USE SOLAR HEAT TO MAKE ELECTRICTY $86,175 $394,200 Not Implemented
OK1091 # 05 Y:2023 05 2023 OPTIMIZE PLANT POWER FACTOR $2,210 $9,834 Implemented
OK1090 # 01 Y:2023 01 2023 USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER $76,727 $51,456 Implemented
OK1090 # 02 Y:2023 02 2023 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $172 $530 Implemented
OK1090 # 03 Y:2023 03 2023 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,602 $1,797 Implemented
OK1090 # 04 Y:2023 04 2023 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,316 $3,638 Implemented
OK1090 # 05 Y:2023 05 2023 USE SOLAR HEAT TO MAKE ELECTRICTY $68,844 $438,000 Not Implemented
OK1089 # 01 Y:2023 01 2023 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,064 $22,000 Implemented