Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,644
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0108 # 01 Y:2013 | 01 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $39,709 | $0 | Implemented |
DL0108 # 02 Y:2013 | 02 | 2013 | ADJUST VENTS TO MINIMIZE ENERGY USE | $3,279 | $0 | Not Implemented |
DL0108 # 03 Y:2013 | 03 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $13,367 | $0 | Implemented |
DL0108 # 04 Y:2013 | 04 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,687 | $270 | Implemented |
DL0108 # 05 Y:2013 | 05 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $500 | $200 | Implemented |
DL0108 # 06 Y:2013 | 06 | 2013 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $2,400 | $400 | Not Implemented |
DL0108 # 07 Y:2013 | 07 | 2013 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $543 | $0 | Implemented |
DL0108 # 08 Y:2013 | 08 | 2013 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $186,000 | $500,000 | Not Implemented |
WV0473 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,047 | $31,578 | Not Implemented |
WV0473 # 02 Y:2013 | 02 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,907 | $8,793 | Not Implemented |
WV0473 # 03 Y:2013 | 03 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,804 | $1,700 | Implemented |
WV0473 # 04 Y:2013 | 04 | 2013 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $3,703 | $1,000 | Implemented |
WV0473 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,539 | $7,466 | Implemented |
WV0473 # 06 Y:2013 | 06 | 2013 | INSULATE BARE EQUIPMENT | $2,574 | $3,281 | Implemented |
WV0473 # 07 Y:2013 | 07 | 2013 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,724 | $617 | Not Implemented |
WV0473 # 08 Y:2013 | 08 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,529 | $3,263 | Not Implemented |
WV0473 # 09 Y:2013 | 09 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $497 | $566 | Implemented |
WV0473 # 10 Y:2013 | 10 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $408 | $29 | Implemented |
LE0363 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $59,031 | $85,300 | Implemented |
LE0363 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,371 | $13,013 | Not Implemented |
LE0363 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,725 | $20,280 | Not Implemented |
LE0363 # 04 Y:2013 | 04 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,978 | $1,000 | Implemented |
LE0363 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,529 | $2,139 | Implemented |
LE0363 # 06 Y:2013 | 06 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,405 | $21,000 | Not Implemented |
LE0363 # 07 Y:2013 | 07 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,878 | $3,800 | Implemented |