Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,629
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0031 # 09 Y:1988 | 09 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $118 | $225 | Not Implemented |
AM0032 # 01 Y:1988 | 01 | 1988 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $3,735 | $6,790 | Not Implemented |
AM0032 # 02 Y:1988 | 02 | 1988 | COMBINE UTILITY METERS | $1,450 | $2,000 | Not Implemented |
AM0032 # 03 Y:1988 | 03 | 1988 | INSTALL / REPAIR INSULATION ON STEAM LINES | $115 | $94 | Not Implemented |
AM0032 # 04 Y:1988 | 04 | 1988 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $1,193 | $504 | Not Implemented |
AM0032 # 05 Y:1988 | 05 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,096 | $0 | Implemented |
AM0032 # 06 Y:1988 | 06 | 1988 | IMPROVE LUBRICATION PRACTICES | $640 | $0 | Implemented |
AM0032 # 07 Y:1988 | 07 | 1988 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $671 | $2,325 | Implemented |
AM0032 # 08 Y:1988 | 08 | 1988 | INSTALL SET-BACK TIMERS | $325 | $0 | Implemented |
AM0032 # 09 Y:1988 | 09 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $72 | $162 | Implemented |
AM0033 # 01 Y:1988 | 01 | 1988 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,218 | $49,800 | Not Implemented |
AM0033 # 02 Y:1988 | 02 | 1988 | USE OPTIMUM THICKNESS INSULATION | $4,089 | $6,575 | Not Implemented |
AM0033 # 03 Y:1988 | 03 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,800 | $16,400 | Not Implemented |
AM0033 # 04 Y:1988 | 04 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,454 | $810 | Implemented |
AM0033 # 05 Y:1988 | 05 | 1988 | USE OPTIMUM THICKNESS INSULATION | $2,827 | $4,000 | Not Implemented |
AM0033 # 06 Y:1988 | 06 | 1988 | INSULATE BARE EQUIPMENT | $4,496 | $11,180 | Not Implemented |
AM0033 # 07 Y:1988 | 07 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,210 | $11,080 | Not Implemented |
AM0033 # 08 Y:1988 | 08 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,107 | $0 | Not Implemented |
AM0033 # 09 Y:1988 | 09 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $460 | $144 | Not Implemented |
AM0033 # 10 Y:1988 | 10 | 1988 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $393 | $300 | Implemented |
AM0033 # 11 Y:1988 | 11 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $279 | $1,000 | Not Implemented |
AM0033 # 12 Y:1988 | 12 | 1988 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $135 | $0 | Not Implemented |
AM0033 # 13 Y:1988 | 13 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $50 | $152 | Not Implemented |
AM0034 # 01 Y:1988 | 01 | 1988 | INSTALL SET-BACK TIMERS | $275 | $0 | Implemented |