Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
89,602
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UU0067 # 03 Y:2004 | 03 | 2004 | REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS | $495 | $400 | Not Implemented |
UU0067 # 04 Y:2004 | 04 | 2004 | INSTALL WIND POWERED ELECTRIC GENERATOR | $0 | $0 | Implemented |
UU0067 # 05 Y:2004 | 05 | 2004 | INSTALL WIND POWERED ELECTRIC GENERATOR | $0 | $40,000 | Not Implemented |
UU0067 # 06 Y:2004 | 06 | 2004 | TREAT AND REUSE RINSE WATERS | $635,880 | $1,705,000 | Not Implemented |
SD0348 # 01 Y:2004 | 01 | 2004 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $12,921 | $12,655 | Not Implemented |
SD0348 # 02 Y:2004 | 02 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,682 | $2,600 | Not Implemented |
SD0348 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,371 | $747 | Not Implemented |
SD0348 # 04 Y:2004 | 04 | 2004 | USE PHOTOCELL CONTROLS | $1,538 | $1,720 | Not Implemented |
SD0348 # 05 Y:2004 | 05 | 2004 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,553 | $18,500 | Not Implemented |
SD0348 # 06 Y:2004 | 06 | 2004 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $70,166 | $43,083 | Not Implemented |
SD0348 # 07 Y:2004 | 07 | 2004 | INSTALL AUTOMATIC PACKING EQUIPMENT | $2,935 | $3,500 | Not Implemented |
SU0194 # 01 Y:2004 | 01 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $662 | $0 | Implemented |
SU0194 # 02 Y:2004 | 02 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $734 | $11 | Implemented |
SU0194 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,623 | $1,616 | Implemented |
SU0194 # 04 Y:2004 | 04 | 2004 | INSULATE BARE EQUIPMENT | $2,404 | $868 | Implemented |
SU0194 # 05 Y:2004 | 05 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,484 | $576 | Implemented |
SU0194 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $136 | $154 | Implemented |
SU0194 # 07 Y:2004 | 07 | 2004 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $1,122 | $2,975 | Not Implemented |
LL0202 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $69,470 | $20,680 | Implemented |
LL0202 # 02 Y:2004 | 02 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,991 | $16,845 | Not Implemented |
LL0202 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,972 | $500 | Implemented |
LL0202 # 04 Y:2004 | 04 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,675 | $30 | Implemented |
LL0202 # 05 Y:2004 | 05 | 2004 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $3,376 | $135 | Not Implemented |
LL0202 # 06 Y:2004 | 06 | 2004 | INSTALL OCCUPANCY SENSORS | $1,329 | $390 | Not Implemented |
LL0202 # 07 Y:2004 | 07 | 2004 | USE PHOTOCELL CONTROLS | $726 | $150 | Not Implemented |