IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,377

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0159 # 06 Y:1985 06 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,436 $885 Implemented
OK0159 # 07 Y:1985 07 1985 INSTALL SET-BACK TIMERS $380 $90 Not Implemented
OK0159 # 08 Y:1985 08 1985 INSTALL / REPAIR INSULATION ON STEAM LINES $675 $175 Implemented
OK0160 # 01 Y:1985 01 1985 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $622 $100 Implemented
OK0160 # 02 Y:1985 02 1985 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,464 $300 Implemented
OK0160 # 03 Y:1985 03 1985 USE RADIANT HEATER FOR SPOT HEATING $2,869 $5,000 Not Implemented
OK0160 # 04 Y:1985 04 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $386 $500 Not Implemented
OK0161 # 01 Y:1985 01 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,880 $874 Implemented
OK0161 # 02 Y:1985 02 1985 OPTIMIZE PLANT POWER FACTOR $2,436 $5,915 Implemented
OK0161 # 03 Y:1985 03 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $240 $95 Implemented
OK0161 # 04 Y:1985 04 1985 RECOVER WASTE HEAT FROM EQUIPMENT $2,080 $100 Implemented
OK0161 # 05 Y:1985 05 1985 USE RADIANT HEATER FOR SPOT HEATING $11,300 $3,959 Implemented
OK0161 # 06 Y:1985 06 1985 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $3,733 $3,500 Not Implemented
OK0162 # 01 Y:1985 01 1985 INSTALL TIMERS AND/OR THERMOSTATS $6,361 $1,022 Not Implemented
OK0162 # 02 Y:1985 02 1985 OPTIMIZE PLANT POWER FACTOR $900 $2,355 Not Implemented
OK0162 # 03 Y:1985 03 1985 INSTALL / REPAIR INSULATION ON STEAM LINES $799 $400 Not Implemented
OK0162 # 04 Y:1985 04 1985 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $146 $310 Not Implemented
OK0162 # 05 Y:1985 05 1985 REDESIGN PROCESS $529 $33 Not Implemented
OK0162 # 06 Y:1985 06 1985 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,273 $10,000 Not Implemented
OK0163 # 01 Y:1985 01 1985 INSTALL TIMERS AND/OR THERMOSTATS $257 $360 Implemented
OK0163 # 02 Y:1985 02 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $80 $138 Implemented
OK0163 # 03 Y:1985 03 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $720 $200 Implemented
OK0163 # 04 Y:1985 04 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $61 $0 Implemented
OK0163 # 05 Y:1985 05 1985 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $110 $0 Implemented
OK0163 # 06 Y:1985 06 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $258 $139 Implemented