Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,230
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0182 # 15 Y:2011 | 15 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $110 | $0 | Not Implemented |
BD0392 # 01 Y:2011 | 01 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $9,888 | $5,500 | Not Implemented |
BD0392 # 02 Y:2011 | 02 | 2011 | USE SOLAR HEAT TO MAKE ELECTRICTY | $20,276 | $73,000 | Not Implemented |
BD0392 # 03 Y:2011 | 03 | 2011 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $6,856 | $55,000 | Implemented |
BD0392 # 04 Y:2011 | 04 | 2011 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,087 | $7,610 | Not Implemented |
BD0392 # 05 Y:2011 | 05 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,781 | $3,500 | Implemented |
BD0392 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,411 | $1,001 | Not Implemented |
BD0392 # 07 Y:2011 | 07 | 2011 | INSTALL OCCUPANCY SENSORS | $1,030 | $1,000 | Not Implemented |
BD0392 # 08 Y:2011 | 08 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $419 | $10 | Implemented |
BD0392 # 09 Y:2011 | 09 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $241 | $250 | Not Implemented |
BD0392 # 10 Y:2011 | 10 | 2011 | MINIMIZE WATER USAGE | $1,525 | $1,800 | Not Implemented |
BD0392 # 11 Y:2011 | 11 | 2011 | RESCHEDULE BREAKS TO ALLOW FOR CONTINUOUS PRODUCTION | $67,284 | $10 | Not Implemented |
BD0392 # 12 Y:2011 | 12 | 2011 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $12,800 | $1,600 | Implemented |
DL0070 # 01 Y:2011 | 01 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $136,635 | $120,000 | Implemented |
DL0070 # 02 Y:2011 | 02 | 2011 | REDUCE VENTILATION AIR | $12,200 | $200 | Implemented |
DL0070 # 03 Y:2011 | 03 | 2011 | REDUCE VENTILATION AIR | $2,160 | $45 | Not Implemented |
DL0070 # 04 Y:2011 | 04 | 2011 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $14,330 | $500 | Implemented |
DL0070 # 05 Y:2011 | 05 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,782 | $1,800 | Not Implemented |
DL0070 # 06 Y:2011 | 06 | 2011 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $104,177 | $157,000 | Implemented |
DL0070 # 07 Y:2011 | 07 | 2011 | USE STEAM SPARGING OR INJECTIONS IN PLACE OF INDIRECT HEATING | $4,600 | $10,000 | Not Implemented |
DL0070 # 08 Y:2011 | 08 | 2011 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $21,528 | $52,000 | Implemented |
DL0070 # 09 Y:2011 | 09 | 2011 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,701 | $10,500 | Not Implemented |
DL0070 # 10 Y:2011 | 10 | 2011 | USE SOLAR HEAT TO MAKE ELECTRICTY | $33,730 | $1,035,000 | Not Implemented |
SD0435 # 01 Y:2011 | 01 | 2011 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $704 | $0 | Implemented |
SD0435 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,875 | $700 | Implemented |