Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,666
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0281 # 09 Y:2009 | 09 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $408 | $589 | Implemented |
SU0281 # 10 Y:2009 | 10 | 2009 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $676 | $997 | Not Implemented |
SU0281 # 11 Y:2009 | 11 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,300 | $5,580 | Implemented |
SU0281 # 12 Y:2009 | 12 | 2009 | INSTALL OCCUPANCY SENSORS | $241 | $516 | Implemented |
SU0281 # 13 Y:2009 | 13 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,072 | $4,000 | Implemented |
DL0036 # 01 Y:2009 | 01 | 2009 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $26,142 | $14,000 | Not Implemented |
DL0036 # 02 Y:2009 | 02 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $16,987 | $18,000 | Not Implemented |
DL0036 # 03 Y:2009 | 03 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,802 | $4,000 | Not Implemented |
DL0036 # 04 Y:2009 | 04 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,127 | $1,430 | Not Implemented |
DL0036 # 05 Y:2009 | 05 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,231 | $0 | Implemented |
DL0036 # 06 Y:2009 | 06 | 2009 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $596 | $0 | Implemented |
DL0036 # 07 Y:2009 | 07 | 2009 | INSULATE BARE EQUIPMENT | $231 | $594 | Not Implemented |
DL0036 # 08 Y:2009 | 08 | 2009 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,742 | $10,500 | Not Implemented |
DL0035 # 01 Y:2009 | 01 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $70,852 | $10,000 | Not Implemented |
DL0035 # 02 Y:2009 | 02 | 2009 | REPAIR AND ELIMINATE STEAM LEAKS | $76,620 | $120,000 | Not Implemented |
DL0035 # 03 Y:2009 | 03 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $34,425 | $12,000 | Implemented |
DL0035 # 04 Y:2009 | 04 | 2009 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $28,800 | $44,500 | Not Implemented |
DL0035 # 05 Y:2009 | 05 | 2009 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $4,041 | $0 | Not Implemented |
DL0035 # 06 Y:2009 | 06 | 2009 | USE MINIMUM STEAM OPERATING PRESSURE | $2,530 | $0 | Not Implemented |
MA0650 # 01 Y:2009 | 01 | 2009 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $5,218 | $10,000 | Not Implemented |
MA0650 # 02 Y:2009 | 02 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,735 | $0 | Implemented |
MA0650 # 03 Y:2009 | 03 | 2009 | REDUCE VENTILATION AIR | $581 | $2,300 | Implemented |
MA0650 # 04 Y:2009 | 04 | 2009 | REDUCE VENTILATION AIR | $250 | $0 | Implemented |
MA0650 # 05 Y:2009 | 05 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $213 | $0 | Implemented |
UD0796 # 01 Y:2009 | 01 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $17,000 | $4,900 | Implemented |