Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,777
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0148 # 02 Y:1992 | 02 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $86 | $0 | Implemented |
OR0148 # 03 Y:1992 | 03 | 1992 | MINIMIZE WATER USAGE | $1,770 | $574 | Not Implemented |
OR0148 # 04 Y:1992 | 04 | 1992 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $4,487 | $2,700 | Implemented |
OR0148 # 05 Y:1992 | 05 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $934 | $1,000 | Implemented |
OR0148 # 06 Y:1992 | 06 | 1992 | INSULATE BARE EQUIPMENT | $516 | $1,090 | Not Implemented |
OR0148 # 07 Y:1992 | 07 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $544 | $228 | Implemented |
OR0147 # 01 Y:1992 | 01 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $10,344 | $0 | Implemented |
OR0147 # 02 Y:1992 | 02 | 1992 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $125,990 | $0 | Not Implemented |
OR0147 # 03 Y:1992 | 03 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $12,776 | $19,623 | Implemented |
OR0147 # 04 Y:1992 | 04 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,227 | $6,838 | Implemented |
OR0147 # 05 Y:1992 | 05 | 1992 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $21,829 | $150,050 | Not Implemented |
OK0383 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $118 | $423 | Implemented |
OK0383 # 02 Y:1992 | 02 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,589 | $1,399 | Implemented |
OK0383 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $978 | $1,060 | Implemented |
OK0383 # 04 Y:1992 | 04 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $224 | $236 | Implemented |
OK0383 # 05 Y:1992 | 05 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,966 | $0 | Implemented |
OK0383 # 06 Y:1992 | 06 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,621 | $6,979 | Not Implemented |
OK0383 # 07 Y:1992 | 07 | 1992 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,752 | $36,300 | Not Implemented |
OK0385 # 01 Y:1992 | 01 | 1992 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $265 | $280 | Implemented |
OK0385 # 02 Y:1992 | 02 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,839 | $608 | Implemented |
OK0385 # 03 Y:1992 | 03 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $705 | $2,000 | Implemented |
OK0385 # 04 Y:1992 | 04 | 1992 | REPAIR AND ELIMINATE STEAM LEAKS | $980 | $0 | Implemented |
IA0017 # 01 Y:1992 | 01 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,858 | $700 | Implemented |
IA0017 # 02 Y:1992 | 02 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $9,694 | $2,000 | Not Implemented |
IA0017 # 03 Y:1992 | 03 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,603 | $500 | Implemented |