Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,871
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UL0213 # 03 Y:1999 | 03 | 1999 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $93,500 | $12,000 | Implemented |
UL0212 # 01 Y:1998 | 01 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,802 | $100 | n/a |
UL0212 # 02 Y:1998 | 02 | 1998 | OPTIMIZE PLANT POWER FACTOR | $3,040 | $2,176 | n/a |
UL0212 # 03 Y:1998 | 03 | 1998 | MINIMIZE USE OF RAGS THROUGH WORKER TRAINING | $3,175 | $1,625 | n/a |
UL0212 # 04 Y:1998 | 04 | 1998 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $1,567 | $5,070 | n/a |
UL0212 # 05 Y:1998 | 05 | 1998 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $26,000 | $3,120 | n/a |
UL0211 # 01 Y:1998 | 01 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $11,780 | $0 | n/a |
UL0211 # 02 Y:1998 | 02 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $6,350 | $0 | n/a |
UL0211 # 03 Y:1998 | 03 | 1998 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $6,169 | $15,000 | n/a |
UL0210 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,828 | $10,925 | Not Implemented |
UL0210 # 02 Y:1998 | 02 | 1998 | OPTIMIZE PLANT POWER FACTOR | $80,210 | $43,420 | Not Implemented |
UL0210 # 03 Y:1998 | 03 | 1998 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $22,000 | $0 | Implemented |
UL0210 # 04 Y:1998 | 04 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $100,000 | $200,000 | Not Implemented |
UL0207 # 01 Y:1998 | 01 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,709 | $120 | Implemented |
UL0207 # 02 Y:1998 | 02 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,492 | $20 | Implemented |
UL0207 # 03 Y:1998 | 03 | 1998 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $74,500 | $163,800 | Not Implemented |
UL0207 # 04 Y:1998 | 04 | 1998 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $6,000 | $1,320 | Not Implemented |
UL0207 # 05 Y:1998 | 05 | 1998 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $306,800 | $117,500 | Implemented |
UL0208 # 01 Y:1998 | 01 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $33,960 | $0 | Not Implemented |
UL0208 # 02 Y:1998 | 02 | 1998 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $35,850 | $0 | Not Implemented |
UL0208 # 03 Y:1998 | 03 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $24,060 | $0 | Not Implemented |
UL0208 # 04 Y:1998 | 04 | 1998 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $60,000 | $20,000 | Not Implemented |
UL0206 # 01 Y:1998 | 01 | 1998 | OPTIMIZE PLANT POWER FACTOR | $67,516 | $0 | Implemented |
UL0206 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,803 | $0 | Implemented |
UL0206 # 03 Y:1998 | 03 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $28,180 | $0 | Implemented |