Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,002
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0859 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,512 | $10,150 | Not Implemented |
UD0859 # 02 Y:2012 | 02 | 2012 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $581 | $600 | Implemented |
UD0859 # 03 Y:2012 | 03 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,313 | $100 | Not Implemented |
UD0859 # 04 Y:2012 | 04 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,041 | $2,000 | Not Implemented |
UD0859 # 05 Y:2012 | 05 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,953 | $1,000 | Implemented |
UD0859 # 06 Y:2012 | 06 | 2012 | INSTALL / REPAIR INSULATION ON STEAM LINES | $20,256 | $6,033 | Implemented |
UD0859 # 07 Y:2012 | 07 | 2012 | REDUCE EXCESS STEAM BLEEDING | $20,148 | $0 | Implemented |
UD0859 # 08 Y:2012 | 08 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $14,768 | $2,000 | Implemented |
UD0859 # 09 Y:2012 | 09 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,869 | $10,000 | Not Implemented |
UD0859 # 10 Y:2012 | 10 | 2012 | REDUCE EXCESSIVE BOILER BLOWDOWN | $4,657 | $5,000 | Not Implemented |
OK0829 # 01 Y:2012 | 01 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,021 | $1,600 | Implemented |
OK0829 # 02 Y:2012 | 02 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,959 | $33,990 | Not Implemented |
OK0829 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,968 | $260,400 | Not Implemented |
OK0829 # 04 Y:2012 | 04 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $346 | $954 | Not Implemented |
OK0829 # 05 Y:2012 | 05 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $202 | $1,139 | Not Implemented |
OK0829 # 06 Y:2012 | 06 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $5,221 | $7,540 | Not Implemented |
OK0829 # 07 Y:2012 | 07 | 2012 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $2,159 | $417 | Implemented |
OK0829 # 08 Y:2012 | 08 | 2012 | INSTALL SET-BACK TIMERS | $3,516 | $489 | Not Implemented |
OK0829 # 09 Y:2012 | 09 | 2012 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $5,966 | $80,748 | Not Implemented |
OK0829 # 10 Y:2012 | 10 | 2012 | USE RADIANT HEATER FOR SPOT HEATING | $8,164 | $17,500 | Not Implemented |
CO0658 # 01 Y:2012 | 01 | 2012 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $9,430 | $850 | Implemented |
CO0658 # 02 Y:2012 | 02 | 2012 | INSTALL OCCUPANCY SENSORS | $7,240 | $29,960 | Not Implemented |
CO0658 # 03 Y:2012 | 03 | 2012 | USE PHOTOCELL CONTROLS | $6,600 | $4,680 | Not Implemented |
CO0658 # 04 Y:2012 | 04 | 2012 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $5,660 | $550 | Implemented |
CO0658 # 05 Y:2012 | 05 | 2012 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,460 | $9,100 | Not Implemented |