Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,996
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0534 # 07 Y:1997 | 07 | 1997 | USE COUNTER-CURRENT RINSING TO REDUCE RINSE WATER VOLUME (GRAVURE) | $5,196 | $1,000 | Implemented |
OK0534 # 08 Y:1997 | 08 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,814 | $732 | Implemented |
OK0534 # 09 Y:1997 | 09 | 1997 | INSULATE BARE EQUIPMENT | $3,414 | $2,250 | Not Implemented |
OK0534 # 10 Y:1997 | 10 | 1997 | INSULATE BARE EQUIPMENT | $1,464 | $485 | Not Implemented |
OK0534 # 11 Y:1997 | 11 | 1997 | USE COUNTER-CURRENT RINSING TO REDUCE RINSE WATER VOLUME (GRAVURE) | $2,350 | $35,000 | Not Implemented |
OK0534 # 12 Y:1997 | 12 | 1997 | INSULATE BARE EQUIPMENT | $1,232 | $1,004 | Not Implemented |
OK0534 # 13 Y:1997 | 13 | 1997 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $858 | $0 | Implemented |
OD0099 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,007 | $11,490 | Implemented |
OD0099 # 02 Y:1997 | 02 | 1997 | OPERATE BOILERS ON HIGH FIRE SETTING | $1,495 | $1,495 | Implemented |
OD0099 # 03 Y:1997 | 03 | 1997 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $19,847 | $8,500 | Not Implemented |
ND0279 # 01 Y:1997 | 01 | 1997 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $25,063 | $75,000 | Not Implemented |
ND0279 # 02 Y:1997 | 02 | 1997 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $19,775 | $7,000 | Not Implemented |
ND0279 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,005 | $36,799 | Implemented |
ND0279 # 04 Y:1997 | 04 | 1997 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $6,570 | $1,500 | Not Implemented |
ND0279 # 05 Y:1997 | 05 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,396 | $1,000 | Not Implemented |
ND0279 # 06 Y:1997 | 06 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,092 | $1,388 | Not Implemented |
ND0279 # 07 Y:1997 | 07 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $872 | $400 | Not Implemented |
ND0279 # 08 Y:1997 | 08 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $405 | $1,140 | Not Implemented |
ND0279 # 09 Y:1997 | 09 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $196 | $100 | Not Implemented |
ND0279 # 10 Y:1997 | 10 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $174 | $0 | Not Implemented |
ND0279 # 11 Y:1997 | 11 | 1997 | INSTALL OCCUPANCY SENSORS | $173 | $200 | Not Implemented |
ND0279 # 12 Y:1997 | 12 | 1997 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $8,276 | $10,000 | Implemented |
ND0279 # 13 Y:1997 | 13 | 1997 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $450 | $0 | Not Implemented |
ND0279 # 14 Y:1997 | 14 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $300 | $200 | Not Implemented |
ND0279 # 15 Y:1997 | 15 | 1997 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,580 | $0 | Not Implemented |