IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,317

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0146 # 06 Y:1998 06 1998 INSULATE BARE EQUIPMENT $506 $263 Not Implemented
WV0146 # 07 Y:1998 07 1998 RECOVER WASTE HEAT FROM EQUIPMENT $18,084 $2,893 Not Implemented
WV0146 # 08 Y:1998 08 1998 COVER OPEN TANKS $4,417 $699 Implemented
WV0146 # 09 Y:1998 09 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $136 $1,439 Implemented
WV0146 # 10 Y:1998 10 1998 PAY UTILITY BILLS ON TIME $657 $0 Implemented
WV0146 # 11 Y:1998 11 1998 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS $783 $850 Implemented
WV0146 # 12 Y:1998 12 1998 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $5,004 $11,000 Not Implemented
WV0146 # 13 Y:1998 13 1998 CLEAR AND RENT EXISTING SPACE $57,240 $16,800 Not Implemented
WV0146 # 01 Y:1998 01 1998 REDUCE VENTILATION AIR $314 $350 Implemented
WV0146 # 02 Y:1998 02 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $38 $136 Not Implemented
WV0146 # 03 Y:1998 03 1998 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $2,135 $1,000 Implemented
WV0146 # 04 Y:1998 04 1998 INSTALL / REPAIR INSULATION ON STEAM LINES $408 $3,072 Implemented
WV0142 # 01 Y:1998 01 1998 PREHEAT COMBUSTION AIR WITH WASTE HEAT $1,491 $1,400 Not Implemented
WV0142 # 02 Y:1998 02 1998 COVER OPEN TANKS $387 $1,056 Not Implemented
WV0142 # 03 Y:1998 03 1998 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE $152 $316 Not Implemented
WV0142 # 04 Y:1998 04 1998 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $14 $10 Implemented
WV0142 # 05 Y:1998 05 1998 RECOVER WASTE HEAT FROM EQUIPMENT $1,509 $605 Not Implemented
WV0142 # 06 Y:1998 06 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $51 $88 Implemented
WV0142 # 07 Y:1998 07 1998 INSULATE BARE EQUIPMENT $3,358 $1,330 Implemented
WV0142 # 08 Y:1998 08 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $139 $126 Implemented
WV0142 # 09 Y:1998 09 1998 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $1,076 $11,000 Not Implemented
WV0142 # 10 Y:1998 10 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $960 $100 Implemented
WV0142 # 11 Y:1998 11 1998 CROSS-TRAIN PERSONNEL TO AVOID LOST TIME $29,750 $500 Implemented
WV0132 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,146 $271 Implemented
WV0132 # 02 Y:1998 02 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,302 $10,560 Not Implemented