Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,568

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0293 # 04 Y:1997 04 1997 USE MAGNETIC TECHNOLOGY TO TREAT WATER $149,760 $238,000 Implemented
OR0293 # 05 Y:1997 05 1997 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $1,000 $0 Implemented
OR0293 # 06 Y:1997 06 1997 INSTALL AUTOMATIC PACKING EQUIPMENT $48,900 $70,000 Implemented
OR0292 # 01 Y:1997 01 1997 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS $116,300 $0 Implemented
OR0292 # 02 Y:1997 02 1997 USE A DIFFERENT OR RECYCLED RAW MATERIAL $17,850 $0 Implemented
OR0292 # 03 Y:1997 03 1997 USE DECANTING, FLOTATION TO REMOVE CONTAMINANTS $11,080 $2,000 Implemented
OR0292 # 04 Y:1997 04 1997 USE OTHER WASTE CONCENTRATION METHODS $6,602 $10,000 Not Implemented
OR0292 # 05 Y:1997 05 1997 KEEP BOILER TUBES CLEAN $7,179 $500 Implemented
OR0292 # 06 Y:1997 06 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,202 $1,144 Implemented
OR0292 # 07 Y:1997 07 1997 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $12,370 $23,720 Not Implemented
OR0292 # 08 Y:1997 08 1997 OPTIMIZE PLANT POWER FACTOR $8,246 $28,000 Not Implemented
OR0292 # 09 Y:1997 09 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,215 $23,353 Implemented
OR0292 # 10 Y:1997 10 1997 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL $250,000 $0 Implemented
OR0292 # 11 Y:1997 11 1997 ELIMINATE/REDUCE REDUNDANT INSPECTIONS $375,000 $0 Implemented
OR0291 # 01 Y:1997 01 1997 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $35,946 $240 Not Implemented
OR0291 # 02 Y:1997 02 1997 BURN WOOD BY-PRODUCTS FOR HEAT $5,024 $0 Implemented
OR0291 # 03 Y:1997 03 1997 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $814 $0 Implemented
OR0291 # 04 Y:1997 04 1997 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $14,628 $3,460 Not Implemented
OR0291 # 05 Y:1997 05 1997 RECOVER AND REUSE COOLING WATER $1,749 $1,300 Not Implemented
OR0291 # 06 Y:1997 06 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $6,204 $10,103 Not Implemented
OR0291 # 07 Y:1997 07 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $716 $1,471 Not Implemented
OR0291 # 08 Y:1997 08 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $883 $2,029 Implemented
OR0291 # 09 Y:1997 09 1997 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $2,590 $11,350 Not Implemented
OR0287 # 01 Y:1997 01 1997 REVISE RAW MATERIAL SPECS $32,300 $104,000 Not Implemented
OR0287 # 02 Y:1997 02 1997 USE A DIFFERENT OR RECYCLED RAW MATERIAL $17,270 $0 Not Implemented