Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,485
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0579 # 09 Y:2019 | 09 | 2019 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $589 | $1,000 | Implemented |
WV0579 # 10 Y:2019 | 10 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $346 | $33 | Implemented |
WV0578 # 01 Y:2019 | 01 | 2019 | INSULATE BARE EQUIPMENT | $49,796 | $9,417 | Not Implemented |
WV0578 # 02 Y:2019 | 02 | 2019 | UPGRADE CONTROLS ON COMPRESSORS | $13,935 | $4,000 | Not Implemented |
WV0578 # 03 Y:2019 | 03 | 2019 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $9,677 | $17,920 | Not Implemented |
WV0578 # 04 Y:2019 | 04 | 2019 | USE EVAPORATION TO CONCENTRATE MATERIAL | $6,422 | $11,000 | Not Implemented |
WV0578 # 05 Y:2019 | 05 | 2019 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,104 | $3,500 | Implemented |
WV0578 # 06 Y:2019 | 06 | 2019 | DEVELOP A REPAIR/REPLACE POLICY | $5,469 | $692 | Implemented |
WV0578 # 07 Y:2019 | 07 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,576 | $3,000 | Not Implemented |
WV0578 # 08 Y:2019 | 08 | 2019 | MINIMIZE WATER USAGE | $1,375 | $700 | Not Implemented |
WV0578 # 09 Y:2019 | 09 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,217 | $46 | Implemented |
WV0578 # 10 Y:2019 | 10 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $174 | $221 | Implemented |
NC0632 # 01 Y:2019 | 01 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,842 | $21,173 | Not Implemented |
NC0632 # 02 Y:2019 | 02 | 2019 | INSTALL OCCUPANCY SENSORS | $183 | $400 | Not Implemented |
NC0632 # 03 Y:2019 | 03 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $739 | $360 | Implemented |
NC0632 # 04 Y:2019 | 04 | 2019 | UPGRADE CONTROLS ON COMPRESSORS | $357 | $500 | Implemented |
NC0632 # 05 Y:2019 | 05 | 2019 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $43,288 | $500 | Implemented |
UK1903 # 01 Y:2019 | 01 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $515 | $0 | n/a |
UK1903 # 02 Y:2019 | 02 | 2019 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,579 | $0 | n/a |
UK1903 # 03 Y:2019 | 03 | 2019 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,341 | $0 | n/a |
UK1903 # 04 Y:2019 | 04 | 2019 | INSTALL OCCUPANCY SENSORS | $2,357 | $717 | n/a |
UK1903 # 05 Y:2019 | 05 | 2019 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $311 | $1,218 | n/a |
UK1903 # 06 Y:2019 | 06 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $451 | $486 | n/a |
UK1903 # 07 Y:2019 | 07 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,016 | $11,658 | n/a |
UK1903 # 08 Y:2019 | 08 | 2019 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $332 | $0 | n/a |