Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,193
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0250 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,480 | $1,572 | Implemented |
UM0250 # 04 Y:2004 | 04 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,215 | $4,000 | Implemented |
UM0250 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,097 | $1,125 | Implemented |
UM0250 # 06 Y:2004 | 06 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $925 | $1,500 | Not Implemented |
UM0250 # 07 Y:2004 | 07 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $760 | $10,000 | Not Implemented |
UM0249 # 01 Y:2004 | 01 | 2004 | MAINTAIN MACHINES TO REDUCE LEAKS | $78,906 | $4,500 | Implemented |
UM0249 # 02 Y:2004 | 02 | 2004 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $59,835 | $55,000 | Not Implemented |
UM0249 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $20,288 | $20,400 | Implemented |
UM0249 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,027 | $8,138 | Implemented |
UM0249 # 05 Y:2004 | 05 | 2004 | OPTIMIZE PLANT POWER FACTOR | $6,174 | $27,270 | Implemented |
UM0249 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,436 | $975 | Implemented |
UM0247 # 01 Y:2004 | 01 | 2004 | USE RADIANT HEATER FOR SPOT HEATING | $300,078 | $269,346 | Not Implemented |
UM0247 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,882 | $7,500 | Implemented |
UM0247 # 03 Y:2004 | 03 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $12,365 | $6,000 | Not Implemented |
UM0247 # 04 Y:2004 | 04 | 2004 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $10,227 | $11,000 | Not Implemented |
UM0247 # 05 Y:2004 | 05 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $6,051 | $12,000 | Not Implemented |
UM0247 # 06 Y:2004 | 06 | 2004 | INSTALL COMMON HEADER ON COMPRESSORS | $1,888 | $1,100 | Implemented |
UM0246 # 01 Y:2004 | 01 | 2004 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $34,080 | $26,630 | Not Implemented |
UM0246 # 02 Y:2004 | 02 | 2004 | INSULATE BARE EQUIPMENT | $6,140 | $700 | Implemented |
UM0246 # 03 Y:2004 | 03 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,885 | $100 | Implemented |
UM0246 # 04 Y:2004 | 04 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,380 | $500 | Implemented |
UM0246 # 05 Y:2004 | 05 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,165 | $2,000 | Not Implemented |
UM0246 # 06 Y:2004 | 06 | 2004 | ADD AREA LIGHTING SWITCHES | $620 | $600 | Not Implemented |
UM0245 # 01 Y:2004 | 01 | 2004 | REDUCE SCRAP PRODUCTION | $21,060 | $2,288 | Not Implemented |
UM0245 # 02 Y:2004 | 02 | 2004 | REPLACE BOILER | $13,000 | $34,000 | Not Implemented |