IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,380

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0054 # 06 Y:1989 06 1989 INSTALL TIMERS AND/OR THERMOSTATS $330 $900 Not Implemented
AM0054 # 07 Y:1989 07 1989 INSTALL SET-BACK TIMERS $210 $0 Implemented
AM0054 # 08 Y:1989 08 1989 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $195 $250 Not Implemented
AT0121 # 01 Y:1989 01 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $52,560 $22,000 Not Implemented
AT0121 # 02 Y:1989 02 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,502 $10,000 Not Implemented
AT0121 # 03 Y:1989 03 1989 INSTALL TIMERS AND/OR THERMOSTATS $2,153 $1,500 Implemented
AT0121 # 04 Y:1989 04 1989 REPAIR AND ELIMINATE STEAM LEAKS $13,451 $50 Implemented
AT0121 # 05 Y:1989 05 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $837 $616 Implemented
AT0121 # 06 Y:1989 06 1989 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,374 $300 Implemented
AT0121 # 07 Y:1989 07 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $505 $500 Implemented
AT0121 # 08 Y:1989 08 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,196 $1,080 Implemented
CO0141 # 01 Y:1989 01 1989 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $33,200 $6,700 Implemented
CO0141 # 02 Y:1989 02 1989 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,410 $5,000 Implemented
CO0141 # 03 Y:1989 03 1989 INSULATE BARE EQUIPMENT $351 $3,460 Not Implemented
CO0141 # 04 Y:1989 04 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,887 $4,162 Implemented
CO0141 # 05 Y:1989 05 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,494 $2,200 Implemented
CO0141 # 06 Y:1989 06 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,193 $10,000 Not Implemented
CO0141 # 07 Y:1989 07 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $800 $700 Implemented
CO0141 # 08 Y:1989 08 1989 INSTALL TIMERS AND/OR THERMOSTATS $657 $750 Implemented
CO0141 # 09 Y:1989 09 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $307 $359 Implemented
KU0271 # 01 Y:1989 01 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,720 $6,000 Not Implemented
KU0271 # 02 Y:1989 02 1989 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $5,826 $297 Implemented
KU0271 # 03 Y:1989 03 1989 KEEP BOILER TUBES CLEAN $5,300 $1,500 Implemented
KU0271 # 04 Y:1989 04 1989 INSULATE BARE EQUIPMENT $3,940 $900 Not Implemented
KU0271 # 05 Y:1989 05 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,327 $6,000 Not Implemented