Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,304
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0366 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,000 | $14,000 | n/a |
UM0366 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $200 | $200 | n/a |
UM0366 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $139 | $1,000 | Not Implemented |
UM0366 # 04 Y:2010 | 04 | 2010 | INSULATE BARE EQUIPMENT | $2,117 | $596 | Implemented |
UM0366 # 05 Y:2010 | 05 | 2010 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $85 | $31 | Implemented |
UA0051 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $9,487 | $1,000 | Not Implemented |
UA0051 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $29,840 | $10,000 | Implemented |
UA0051 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,427 | $4,500 | Implemented |
UA0051 # 04 Y:2010 | 04 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,331 | $640 | Not Implemented |
UA0051 # 05 Y:2010 | 05 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $8,177 | $5,219 | Implemented |
UA0051 # 06 Y:2010 | 06 | 2010 | PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT | $48,136 | $21,075 | Not Implemented |
UF0432 # 06 Y:2010 | 06 | 2010 | INSTALL COMMON HEADER ON COMPRESSORS | $1,520 | $0 | Not Implemented |
UF0432 # 07 Y:2010 | 07 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,000 | $2,700 | Not Implemented |
UF0432 # 08 Y:2010 | 08 | 2010 | DEVELOP A REPAIR/REPLACE POLICY | $364 | $0 | Not Implemented |
UF0432 # 09 Y:2010 | 09 | 2010 | CLEAN CONDENSER TUBES | $1,343 | $120 | Not Implemented |
UF0432 # 10 Y:2010 | 10 | 2010 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $3,120 | $0 | Not Implemented |
UF0432 # 11 Y:2010 | 11 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $8,637 | $1,500 | Not Implemented |
DL0051 # 01 Y:2010 | 01 | 2010 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,124 | $0 | Implemented |
DL0051 # 02 Y:2010 | 02 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $573 | $0 | Implemented |
DL0051 # 03 Y:2010 | 03 | 2010 | USE SMALL NUMBER OF HIGH OUTPUT UNITS INSTEAD OF MANY SMALL INEFFICIENT UNITS | $940 | $30 | Implemented |
DL0051 # 04 Y:2010 | 04 | 2010 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,500 | $100 | Implemented |
DL0051 # 05 Y:2010 | 05 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $860 | $150 | Not Implemented |
DL0051 # 06 Y:2010 | 06 | 2010 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $4,250 | $960 | Not Implemented |
DL0051 # 07 Y:2010 | 07 | 2010 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $4,473 | $3,840 | Not Implemented |
DL0051 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,720 | $20,796 | Not Implemented |