IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,043

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0471 # 03 Y:2013 03 2013 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $6,454 $6,210 Not Implemented
WV0471 # 04 Y:2013 04 2013 COMBINE UTILITY METERS $5,415 $11,000 Implemented
WV0471 # 05 Y:2013 05 2013 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $5,088 $1,000 Implemented
WV0471 # 06 Y:2013 06 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,860 $310 Implemented
WV0471 # 07 Y:2013 07 2013 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,543 $0 Implemented
WV0471 # 08 Y:2013 08 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,944 $3,375 Not Implemented
WV0471 # 09 Y:2013 09 2013 INSTALL OCCUPANCY SENSORS $1,731 $680 Implemented
WV0471 # 10 Y:2013 10 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,159 $4,625 Implemented
WV0471 # 11 Y:2013 11 2013 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $716 $105 Implemented
WV0471 # 12 Y:2013 12 2013 DISCONNECT BALLASTS $297 $70 Implemented
WV0471 # 13 Y:2013 13 2013 DEVELOP A REPAIR/REPLACE POLICY $124 $426 Implemented
CO0669 # 01 Y:2013 01 2013 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,590 $15,280 Implemented
CO0669 # 02 Y:2013 02 2013 INSULATE BARE EQUIPMENT $4,190 $4,840 Not Implemented
CO0669 # 03 Y:2013 03 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,650 $390 Implemented
OK0859 # 01 Y:2013 01 2013 USE EXISTING DAM TO GENERATE ELECTRICITY $12,404 $65,000 Not Implemented
OK0859 # 02 Y:2013 02 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,187 $7,856 Implemented
OK0859 # 03 Y:2013 03 2013 DISCONNECT BALLASTS $342 $900 Not Implemented
OK0859 # 04 Y:2013 04 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $232 $975 Not Implemented
OK0859 # 05 Y:2013 05 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $327 $2,550 Not Implemented
OK0859 # 06 Y:2013 06 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,550 $3,000 Implemented
OK0859 # 07 Y:2013 07 2013 RECOVER WASTE HEAT FROM EQUIPMENT $3,135 $3,356 Not Implemented
OK0859 # 08 Y:2013 08 2013 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $20,774 $7,707 Not Implemented
OK0859 # 09 Y:2013 09 2013 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $11,338 $4,600 Not Implemented
OK0859 # 10 Y:2013 10 2013 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $17,170 $30,000 Implemented
OK0859 # 11 Y:2013 11 2013 INSTALL SET-BACK TIMERS $1,753 $460 Not Implemented