Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,666
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0046 # 03 Y:2009 | 03 | 2009 | INSTALL OCCUPANCY SENSORS | $18,406 | $1,380 | Implemented |
MZ0046 # 04 Y:2009 | 04 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $53,749 | $1,300 | Implemented |
MZ0046 # 05 Y:2009 | 05 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $10,771 | $0 | Implemented |
MZ0046 # 06 Y:2009 | 06 | 2009 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $8,620 | $1,800 | Implemented |
MZ0046 # 07 Y:2009 | 07 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $205,683 | $30,000 | Not Implemented |
MZ0046 # 08 Y:2009 | 08 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,483 | $0 | Implemented |
MZ0046 # 09 Y:2009 | 09 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $10,100 | $8,000 | Implemented |
WV0398 # 01 Y:2009 | 01 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $413,866 | $803,660 | Not Implemented |
WV0398 # 02 Y:2009 | 02 | 2009 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $165,791 | $85,600 | Not Implemented |
WV0398 # 03 Y:2009 | 03 | 2009 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $97,378 | $120,000 | Not Implemented |
WV0398 # 04 Y:2009 | 04 | 2009 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $75,243 | $72,000 | Not Implemented |
WV0398 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,098 | $44,783 | Not Implemented |
WV0398 # 06 Y:2009 | 06 | 2009 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $11,848 | $3,759 | Not Implemented |
WV0398 # 07 Y:2009 | 07 | 2009 | DEVELOP A REPAIR/REPLACE POLICY | $11,204 | $793 | Implemented |
WV0398 # 08 Y:2009 | 08 | 2009 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $10,882 | $1,000 | Implemented |
WV0398 # 09 Y:2009 | 09 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,891 | $900 | Implemented |
WV0398 # 10 Y:2009 | 10 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,120 | $0 | Not Implemented |
WV0398 # 11 Y:2009 | 11 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,235 | $419 | Implemented |
WV0398 # 12 Y:2009 | 12 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,839 | $3,121 | Not Implemented |
WV0398 # 13 Y:2009 | 13 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,767 | $75 | Not Implemented |
WV0398 # 14 Y:2009 | 14 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,089 | $245 | Not Implemented |
WV0398 # 15 Y:2009 | 15 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,030 | $0 | Implemented |
WV0398 # 16 Y:2009 | 16 | 2009 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,732 | $1,075 | Not Implemented |
WV0398 # 17 Y:2009 | 17 | 2009 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $606 | $60 | Not Implemented |
MS0347 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,438 | $6,453 | Not Implemented |