Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,315

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0146 # 08 Y:1996 08 1996 TURN OFF EQUIPMENT WHEN NOT IN USE $129 $0 Implemented
IA0146 # 09 Y:1996 09 1996 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $824 $3,224 Not Implemented
IA0145 # 01 Y:1996 01 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $27,015 $50 Not Implemented
IA0145 # 02 Y:1996 02 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,045 $420 Implemented
IA0145 # 03 Y:1996 03 1996 AIR CONDITION ONLY SPACE NECESSARY $43,340 $44,269 Not Implemented
IA0145 # 04 Y:1996 04 1996 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $51,850 $100,800 Not Implemented
IA0145 # 05 Y:1996 05 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $19,046 $65,284 Implemented
IA0145 # 06 Y:1996 06 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,407 $1,998 Implemented
IA0145 # 07 Y:1996 07 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,520 $7,060 Implemented
IA0145 # 08 Y:1996 08 1996 RECOVER WASTE HEAT FROM EQUIPMENT $1,764 $2,410 Not Implemented
IA0145 # 09 Y:1996 09 1996 RECOVER WASTE HEAT FROM EQUIPMENT $923 $1,100 Not Implemented
IA0144 # 01 Y:1996 01 1996 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $2,869 $6,067 Implemented
IA0144 # 02 Y:1996 02 1996 INSTALL OCCUPANCY SENSORS $2,554 $1,447 Implemented
IA0144 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $927 $2,091 Implemented
IA0144 # 04 Y:1996 04 1996 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $500 $513 Implemented
IA0144 # 05 Y:1996 05 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $232 $307 Implemented
IA0144 # 06 Y:1996 06 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $134 $235 Implemented
IA0144 # 07 Y:1996 07 1996 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $174 $68 Implemented
IA0144 # 08 Y:1996 08 1996 USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME $1,096 $1,200 Implemented
IA0138 # 01 Y:1996 01 1996 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $11,803 $7,955 Implemented
IA0138 # 02 Y:1996 02 1996 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $4,117 $2,710 Implemented
IA0138 # 03 Y:1996 03 1996 INSULATE BARE EQUIPMENT $1,352 $6,338 Implemented
IA0138 # 04 Y:1996 04 1996 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,468 $2,301 Implemented
IA0138 # 05 Y:1996 05 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $526 $620 Implemented
IA0138 # 06 Y:1996 06 1996 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES $105,000 $142,000 Not Implemented