IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,738

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AR0004 # 04 Y:1993 04 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,456 $3,500 Implemented
AR0003 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,643 $3,447 Implemented
AR0003 # 02 Y:1993 02 1993 ADD AREA LIGHTING SWITCHES $25,255 $40,272 Implemented
AR0003 # 03 Y:1993 03 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,109 $3,360 Implemented
AR0003 # 04 Y:1993 04 1993 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $9,806 $3,750 Implemented
AR0002 # 01 Y:1993 01 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,244 $230 Implemented
AR0002 # 02 Y:1993 02 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,622 $620 Implemented
AR0002 # 03 Y:1993 03 1993 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $1,739 $600 Not Implemented
AR0002 # 04 Y:1993 04 1993 REPAIR AND ELIMINATE STEAM LEAKS $1,845 $475 Implemented
AR0002 # 05 Y:1993 05 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $387 $1,000 Implemented
AR0001 # 01 Y:1993 01 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,172 $200 Implemented
AR0001 # 02 Y:1993 02 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $13,336 $620 Implemented
AR0001 # 03 Y:1993 03 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $14,158 $21,800 Implemented
AR0001 # 04 Y:1993 04 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $680 $70 Implemented
AR0001 # 05 Y:1993 05 1993 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $11,028 $3,400 Not Implemented
AR0001 # 06 Y:1993 06 1993 USE STEAM PRESSURE REDUCTION TO GENERATE POWER $33,492 $25,300 Implemented
AR0001 # 07 Y:1993 07 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,591 $227 Implemented
OK0398 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,312 $3,809 Not Implemented
OK0398 # 02 Y:1993 02 1993 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $1,494 $898 Implemented
OK0398 # 03 Y:1993 03 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $864 $0 Implemented
OK0398 # 04 Y:1993 04 1993 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $779 $1,600 Implemented
OK0398 # 05 Y:1993 05 1993 INSULATE BARE EQUIPMENT $238 $527 Not Implemented
OK0398 # 06 Y:1993 06 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $179 $217 Not Implemented
OK0343 # 01 Y:1991 01 1991 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $26,827 $0 Implemented
OK0343 # 02 Y:1991 02 1991 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $17,827 $31,500 Implemented