Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,636
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0025 # 05 Y:1995 | 05 | 1995 | INSULATE BARE EQUIPMENT | $2,170 | $4,480 | Not Implemented |
MS0023 # 01 Y:1995 | 01 | 1995 | OPTIMIZE PLANT POWER FACTOR | $7,796 | $4,500 | Not Implemented |
MS0023 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $606 | $2,134 | Not Implemented |
MS0023 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,350 | $43,100 | Not Implemented |
MS0023 # 04 Y:1995 | 04 | 1995 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $918 | $2,400 | Not Implemented |
MS0023 # 05 Y:1995 | 05 | 1995 | INSTALL TIMERS AND/OR THERMOSTATS | $577 | $690 | Not Implemented |
MS0023 # 06 Y:1995 | 06 | 1995 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $839 | $120 | Implemented |
MS0022 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,227 | $6,171 | Implemented |
MS0022 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,855 | $16,900 | Not Implemented |
MS0022 # 03 Y:1995 | 03 | 1995 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,963 | $0 | Implemented |
MS0022 # 04 Y:1995 | 04 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,414 | $1,500 | Not Implemented |
MS0022 # 05 Y:1995 | 05 | 1995 | USE WATER ON AIR CONDITIONING EXCHANGER TO IMPROVE HEAT TRANSFER AND INCREASE AIR CONDITIONER EFFICIENCY | $1,209 | $3,900 | Not Implemented |
MS0021 # 01 Y:1995 | 01 | 1995 | OPTIMIZE PLANT POWER FACTOR | $22,852 | $26,750 | Not Implemented |
MS0021 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,588 | $4,300 | Not Implemented |
MS0021 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,130 | $1,936 | Not Implemented |
MS0021 # 04 Y:1995 | 04 | 1995 | BURN A LESS EXPENSIVE GRADE OF FUEL | $17,678 | $75,000 | Not Implemented |
MS0021 # 05 Y:1995 | 05 | 1995 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $950 | $600 | Not Implemented |
MS0021 # 06 Y:1995 | 06 | 1995 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $4,126 | $0 | Not Implemented |
MS0020 # 01 Y:1995 | 01 | 1995 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $8,151 | $1,500 | Not Implemented |
MS0020 # 02 Y:1995 | 02 | 1995 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $6,400 | $18,000 | Not Implemented |
MS0020 # 03 Y:1995 | 03 | 1995 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,180 | $8,000 | Implemented |
MS0020 # 04 Y:1995 | 04 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,412 | $0 | Implemented |
MS0020 # 05 Y:1995 | 05 | 1995 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $687 | $2,000 | Not Implemented |
MS0020 # 06 Y:1995 | 06 | 1995 | INSTALL OCCUPANCY SENSORS | $220 | $150 | Not Implemented |
MS0019 # 01 Y:1995 | 01 | 1995 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,016 | $10,000 | Not Implemented |