Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
83
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0293 # 05 Y:1986 | 05 | 1986 | TURN OFF EQUIPMENT WHEN NOT IN USE | $640 | $0 | Implemented |
TN0293 # 07 Y:1986 | 07 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $625 | $180 | Implemented |
TN0293 # 01 Y:1986 | 01 | 1986 | INSULATE BARE EQUIPMENT | $13,716 | $2,811 | Implemented |
AT0053 # 04 Y:1986 | 04 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $15,065 | $2,000 | Implemented |
TN0283 # 05 Y:1986 | 05 | 1986 | INSULATE BARE EQUIPMENT | $3,742 | $660 | Implemented |
TN0283 # 06 Y:1986 | 06 | 1986 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,130 | $2,600 | Implemented |
LT0065 # 02 Y:1986 | 02 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,690 | $2,240 | Implemented |
LT0065 # 01 Y:1986 | 01 | 1986 | INSULATE BARE EQUIPMENT | $14,973 | $9,276 | Implemented |
AT0053 # 05 Y:1986 | 05 | 1986 | IMPROVE LUBRICATION PRACTICES | $35,749 | $0 | Implemented |
LT0065 # 04 Y:1986 | 04 | 1986 | ISOLATE HOT OR COLD EQUIPMENT | $2,852 | $0 | Implemented |
AT0053 # 03 Y:1986 | 03 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $25,442 | $5,000 | Implemented |
AT0053 # 02 Y:1986 | 02 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $7,692 | $800 | Implemented |
AT0053 # 01 Y:1986 | 01 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,839 | $1,967 | Implemented |
TN0283 # 04 Y:1986 | 04 | 1986 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $13,182 | $940 | Implemented |
TN0283 # 01 Y:1986 | 01 | 1986 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $31,143 | $20,000 | Implemented |
LT0065 # 03 Y:1986 | 03 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $7,050 | $7,500 | Implemented |
MA0072 # 06 Y:1986 | 06 | 1986 | KEEP BOILER TUBES CLEAN | $3,296 | $750 | Implemented |
MA0072 # 02 Y:1986 | 02 | 1986 | REPAIR OR REPLACE STEAM TRAPS | $13,251 | $600 | Implemented |
MA0072 # 04 Y:1986 | 04 | 1986 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,691 | $720 | Implemented |
MA0071 # 07 Y:1986 | 07 | 1986 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $2,326 | $15,600 | Implemented |
MA0071 # 08 Y:1986 | 08 | 1986 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $3,104 | $6,688 | Implemented |
MA0071 # 03 Y:1986 | 03 | 1986 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $126,986 | $6,650 | Implemented |
MA0071 # 02 Y:1986 | 02 | 1986 | INSULATE BARE EQUIPMENT | $13,827 | $2,280 | Implemented |
MA0072 # 01 Y:1986 | 01 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,220 | $200 | Implemented |
MA0071 # 04 Y:1986 | 04 | 1986 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $27,051 | $2,280 | Implemented |