Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

61

matching recommendations
Reset
SIC 2034 Dehydrated Fruits, Vegetables, Soups
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0314 # 01 Y:2005 01 2005 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $4,353 $0 Implemented
SF0314 # 11 Y:2005 11 2005 USE LESS WASTEFUL PACKAGING $2,285 $0 Not Implemented
SF0314 # 10 Y:2005 10 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $447 $2,408 Not Implemented
SF0314 # 09 Y:2005 09 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,342 $4,848 Implemented
SF0314 # 08 Y:2005 08 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,436 $5,848 Implemented
SF0314 # 07 Y:2005 07 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,127 $2,564 Not Implemented
SF0314 # 05 Y:2005 05 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,186 $14,112 Not Implemented
SF0314 # 04 Y:2005 04 2005 INSTALL / REPAIR INSULATION ON STEAM LINES $1,926 $807 Not Implemented
SF0314 # 03 Y:2005 03 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $258 $0 Implemented
SF0314 # 02 Y:2005 02 2005 REPAIR AND ELIMINATE STEAM LEAKS $6,788 $0 Implemented
SF0314 # 06 Y:2005 06 2005 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $20,484 $30,250 Not Implemented
SF0167 # 05 Y:1999 05 1999 INSTALL OCCUPANCY SENSORS $1,796 $1,080 Not Implemented
SF0167 # 01 Y:1999 01 1999 REPAIR AND ELIMINATE STEAM LEAKS $9,860 $175 Not Implemented
SF0167 # 02 Y:1999 02 1999 INCREASE AMOUNT OF CONDENSATE RETURNED $2,924 $0 Not Implemented
SF0167 # 03 Y:1999 03 1999 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $7,516 $1,500 Not Implemented
SF0167 # 04 Y:1999 04 1999 INCREASE AMOUNT OF CONDENSATE RETURNED $9,607 $5,759 Not Implemented
SF0167 # 06 Y:1999 06 1999 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,077 $4,185 Not Implemented
SF0167 # 07 Y:1999 07 1999 INCREASE AMOUNT OF CONDENSATE RETURNED $5,150 $8,430 Not Implemented
SF0167 # 08 Y:1999 08 1999 INSULATE FEEDWATER TANK $601 $1,327 Not Implemented
SF0167 # 09 Y:1999 09 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,353 $30,890 Not Implemented
NV0090 # 01 Y:1997 01 1997 INSULATE BARE EQUIPMENT $9,086 $58,500 Implemented
NV0090 # 02 Y:1997 02 1997 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $124 $0 Implemented
SF0104 # 11 Y:1996 11 1996 MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT $171,634 $672,500 Not Implemented
SF0104 # 10 Y:1996 10 1996 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $932 $500 Not Implemented
SF0104 # 04 Y:1996 04 1996 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,011 $4,970 Implemented