IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

98

matching recommendations
Reset
SIC 22 Textile Mill Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0155 # 09 Y:1998 09 1998 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $75,844 $200,000 Not Implemented
SF0155 # 10 Y:1998 10 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,609 $52,880 Not Implemented
SF0155 # 12 Y:1998 12 1998 RECOVER AND REUSE WASTE MATERIAL $18,170 $0 Not Implemented
SF0155 # 13 Y:1998 13 1998 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $1,200 $120 Not Implemented
SF0155 # 14 Y:1998 14 1998 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $2,520 $120 Not Implemented
SF0155 # 15 Y:1998 15 1998 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $16,728 $120,000 Not Implemented
SF0155 # 16 Y:1998 16 1998 $408,564 $500,000 Not Implemented
SF0155 # 17 Y:1998 17 1998 $75,299 $142,000 Not Implemented
SF0155 # 18 Y:1998 18 1998 $50,000 $240,200 Not Implemented
SF0100 # 06 Y:1996 06 1996 TREAT AND REUSE RINSE WATERS $87,457 $173,000 Not Implemented
SF0100 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $275 $253 Not Implemented
SF0100 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,710 $5,640 Not Implemented
SF0100 # 03 Y:1996 03 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $303 $720 Not Implemented
SF0100 # 04 Y:1996 04 1996 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $4,132 $8,500 Not Implemented
SF0100 # 05 Y:1996 05 1996 INSTALL / REPAIR INSULATION ON STEAM LINES $970 $1,183 Not Implemented
SD0103 # 04 Y:1995 04 1995 RECOVER WASTE HEAT FROM EQUIPMENT $65,923 $63,000 Not Implemented
SD0103 # 07 Y:1995 07 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,708 $1,432 Implemented
SD0103 # 06 Y:1995 06 1995 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $27,668 $0 Implemented
SD0103 # 05 Y:1995 05 1995 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $34,998 $20,000 Not Implemented
SD0103 # 03 Y:1995 03 1995 COVER OPEN TANKS $62,441 $45,735 Not Implemented
SD0103 # 02 Y:1995 02 1995 INSULATE BARE EQUIPMENT $10,901 $6,835 Not Implemented
SD0103 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $13,776 $14,090 Implemented
SD0102 # 06 Y:1995 06 1995 INSTALL OCCUPANCY SENSORS $1,322 $1,614 Not Implemented
SD0102 # 05 Y:1995 05 1995 INSTALL SPECTRAL REFLECTORS / DELAMP $11,205 $9,725 Not Implemented
SD0102 # 04 Y:1995 04 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,830 $11,141 Implemented