Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
384
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0004 # 09 Y:1993 | 09 | 1993 | MOVE BOILER TO MORE EFFICIENT LOCATION | $414 | $639 | Implemented |
SF0004 # 10 Y:1993 | 10 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $298 | $158 | Not Implemented |
SD0060 # 01 Y:1993 | 01 | 1993 | COVER OPEN TANKS | $1,443 | $85 | Implemented |
SD0060 # 02 Y:1993 | 02 | 1993 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,816 | $10,500 | Implemented |
SD0060 # 03 Y:1993 | 03 | 1993 | COVER OPEN TANKS | $96 | $54 | Not Implemented |
SD0060 # 04 Y:1993 | 04 | 1993 | TURN OFF EQUIPMENT WHEN NOT IN USE | $748 | $0 | Not Implemented |
SD0060 # 05 Y:1993 | 05 | 1993 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,049 | $0 | Not Implemented |
SD0060 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $690 | $87 | Not Implemented |
SD0060 # 07 Y:1993 | 07 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $403 | $480 | Not Implemented |
SD0060 # 08 Y:1993 | 08 | 1993 | INSTALL SET-BACK TIMERS | $220 | $360 | Not Implemented |
SD0060 # 09 Y:1993 | 09 | 1993 | USE PHOTOCELL CONTROLS | $3,563 | $2,475 | Not Implemented |
SD0060 # 10 Y:1993 | 10 | 1993 | INSTALL TIMERS AND/OR THERMOSTATS | $256 | $300 | Implemented |
SF0003 # 01 Y:1993 | 01 | 1993 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $655 | $192 | Implemented |
SF0003 # 02 Y:1993 | 02 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,485 | $900 | Implemented |
SF0003 # 03 Y:1993 | 03 | 1993 | USE OPTIMUM THICKNESS INSULATION | $3,546 | $4,231 | Implemented |
SF0003 # 04 Y:1993 | 04 | 1993 | INSULATE BARE EQUIPMENT | $453 | $557 | Not Implemented |
SF0003 # 05 Y:1993 | 05 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,118 | $3,875 | Implemented |
SF0003 # 06 Y:1993 | 06 | 1993 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,294 | $14,000 | Implemented |
SF0002 # 01 Y:1993 | 01 | 1993 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,600 | $5,300 | Implemented |
SF0002 # 02 Y:1993 | 02 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $458 | $200 | Implemented |
SF0002 # 03 Y:1993 | 03 | 1993 | RECOVER WASTE HEAT FROM EQUIPMENT | $793 | $1,150 | Not Implemented |
SF0002 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,211 | $572 | Not Implemented |
SF0002 # 05 Y:1993 | 05 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $582 | $985 | Implemented |
SD0059 # 01 Y:1993 | 01 | 1993 | INSTALL / REPAIR INSULATION ON STEAM LINES | $253 | $351 | Not Implemented |
SD0059 # 02 Y:1993 | 02 | 1993 | USE OPTIMUM THICKNESS INSULATION | $251 | $243 | Not Implemented |