IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

522

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0114 # 06 Y:1995 06 1995 INSTALL SPECTRAL REFLECTORS / DELAMP $1,019 $1,505 Implemented
SD0114 # 07 Y:1995 07 1995 INSTALL OCCUPANCY SENSORS $409 $665 Not Implemented
SD0114 # 08 Y:1995 08 1995 REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS $1,925 $0 Not Implemented
SD0114 # 09 Y:1995 09 1995 TREAT AND REUSE RINSE WATERS $1,529 $2,500 Not Implemented
SF0055 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,011 $1,077 Not Implemented
SF0055 # 02 Y:1995 02 1995 INSTALL OCCUPANCY SENSORS $11,092 $7,040 Not Implemented
SF0055 # 03 Y:1995 03 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $848 $526 Implemented
SF0055 # 04 Y:1995 04 1995 USE SYNTHETIC LUBRICANT $580 $732 Implemented
SF0055 # 05 Y:1995 05 1995 INSULATE FEEDWATER TANK $727 $140 Not Implemented
SF0055 # 06 Y:1995 06 1995 INSULATE BARE EQUIPMENT $27,226 $4,400 Not Implemented
SF0055 # 07 Y:1995 07 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,376 $5,725 Not Implemented
SD0113 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,917 $4,630 Implemented
SD0113 # 02 Y:1995 02 1995 RECOVER AND REUSE COOLING WATER $306 $500 Not Implemented
SD0113 # 03 Y:1995 03 1995 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $611 $500 Implemented
SD0113 # 04 Y:1995 04 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,078 $5,522 Implemented
SD0113 # 05 Y:1995 05 1995 INSTALL SPECTRAL REFLECTORS / DELAMP $1,970 $2,510 Implemented
SD0113 # 06 Y:1995 06 1995 INSTALL OCCUPANCY SENSORS $1,557 $1,576 Not Implemented
SD0113 # 07 Y:1995 07 1995 USE PHOTOCELL CONTROLS $1,674 $106 Implemented
SD0112 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,149 $450 Implemented
SD0112 # 02 Y:1995 02 1995 COVER OPEN TANKS $1,015 $250 Implemented
SD0112 # 03 Y:1995 03 1995 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,144 $1,600 Implemented
SD0112 # 04 Y:1995 04 1995 INSULATE BARE EQUIPMENT $2,282 $563 Implemented
SD0112 # 05 Y:1995 05 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,168 $6,733 Implemented
SD0112 # 06 Y:1995 06 1995 INSTALL SPECTRAL REFLECTORS / DELAMP $5,047 $4,305 Implemented
SD0112 # 07 Y:1995 07 1995 INSTALL OCCUPANCY SENSORS $494 $599 Not Implemented