IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

67

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0188 # 08 Y:1997 08 1997 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $2,503 $0 Implemented
UF0188 # 07 Y:1997 07 1997 INSTALL / REPAIR INSULATION ON STEAM LINES $1,445 $451 Implemented
UF0188 # 06 Y:1997 06 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,996 $1,000 Not Implemented
UF0188 # 05 Y:1997 05 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,344 $1,450 Implemented
UF0188 # 04 Y:1997 04 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $347 $347 Implemented
UF0188 # 03 Y:1997 03 1997 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $477 $133 Implemented
UF0188 # 02 Y:1997 02 1997 INSTALL OCCUPANCY SENSORS $635 $640 Implemented
UF0188 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,535 $3,969 Implemented
UF0188 # 09 Y:1997 09 1997 RECOVERY METALS FROM RINSE WATER(EVAP., ION EXCHANGE, RO, ELECTROLYSIS, ELECTRODIALYSIS) AND REUSE RINSE WATER $4,874 $4,840 Implemented
UF0188 # 10 Y:1997 10 1997 $26,752 $59,000 Not Implemented
UF0188 # 11 Y:1997 11 1997 $79,467 $273,000 Not Implemented
UF0184 # 06 Y:1997 06 1997 INSULATE FEEDWATER TANK $1,304 $200 Implemented
UF0184 # 04 Y:1997 04 1997 INSTALL / REPAIR INSULATION ON STEAM LINES $2,851 $451 Implemented
UF0184 # 07 Y:1997 07 1997 ELIMINATE PRACTICE OF MIXING WASTE STREAMS $1,261 $5,000 Not Implemented
UF0184 # 03 Y:1997 03 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,782 $1,000 Implemented
UF0184 # 01 Y:1997 01 1997 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,816 $15,515 Not Implemented
UF0184 # 05 Y:1997 05 1997 INSULATE BARE EQUIPMENT $1,170 $974 Implemented
UF0184 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $252 $252 Implemented
UF0184 # 10 Y:1997 10 1997 $12,450 $15,000 Implemented
UF0184 # 08 Y:1997 08 1997 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $3,613 $0 Not Implemented
UF0184 # 09 Y:1997 09 1997 $4,655 $1,800 Not Implemented
UF0184 # 11 Y:1997 11 1997 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $2,628 $0 Not Implemented
UF0182 # 06 Y:1997 06 1997 REPLACE BOILER $653 $0 Implemented
UF0182 # 05 Y:1997 05 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $287 $1,000 Implemented
UF0182 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,376 $11,050 Not Implemented