IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

394

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0289 # 05 Y:2001 05 2001 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $8,758 $11,274 Implemented
UF0289 # 01 Y:2001 01 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,791 $2,728 Implemented
UF0289 # 06 Y:2001 06 2001 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $389 $1,895 Not Implemented
UF0289 # 02 Y:2001 02 2001 INSTALL OCCUPANCY SENSORS $2,566 $1,457 Not Implemented
UF0289 # 03 Y:2001 03 2001 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $5,004 $6,175 Implemented
UF0289 # 04 Y:2001 04 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $869 $500 Implemented
UF0289 # 07 Y:2001 07 2001 INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM $35,100 $4,494 Implemented
UF0289 # 08 Y:2001 08 2001 INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM $9,660 $4,612 Implemented
UF0288 # 07 Y:2001 07 2001 INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM $169,000 $176,000 Implemented
UF0288 # 01 Y:2001 01 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,662 $6,465 Not Implemented
UF0288 # 05 Y:2001 05 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $800 $2,000 Not Implemented
UF0288 # 08 Y:2001 08 2001 INSTALL BACK-UP EQUIPMENT $29,400 $64,000 Implemented
UF0288 # 06 Y:2001 06 2001 MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE $720,000 $559,440 Not Implemented
UF0288 # 04 Y:2001 04 2001 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,155 $0 Implemented
UF0288 # 02 Y:2001 02 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,358 $500 Implemented
UF0288 # 03 Y:2001 03 2001 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $18,443 $30,000 Not Implemented
UF0287 # 06 Y:2001 06 2001 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,358 $0 Implemented
UF0287 # 02 Y:2001 02 2001 INSTALL OCCUPANCY SENSORS $1,260 $2,081 Not Implemented
UF0287 # 04 Y:2001 04 2001 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $3,729 $10,788 Not Implemented
UF0287 # 03 Y:2001 03 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,637 $16,038 Not Implemented
UF0287 # 07 Y:2001 07 2001 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $9,303 $225 Not Implemented
UF0287 # 09 Y:2001 09 2001 PAY UTILITY BILLS ON TIME $15,147 $0 Not Implemented
UF0287 # 10 Y:2001 10 2001 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $29,250 $3,000 Implemented
UF0287 # 08 Y:2001 08 2001 INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM $39,000 $5,247 Implemented
UF0287 # 01 Y:2001 01 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,092 $920 Implemented