Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

53

matching recommendations
Reset
NAICS 331 Primary Metal Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0848 # 03 Y:2008 03 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $340 $1,000 Implemented
GT0848 # 02 Y:2008 02 2008 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT $180,800 $541,073 Not Implemented
GT0848 # 01 Y:2008 01 2008 RECOVER WASTE HEAT FROM EQUIPMENT $11,250 $19,500 Not Implemented
GT0848 # 06 Y:2008 06 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,164 $10,000 Not Implemented
GT0815 # 01 Y:2005 01 2005 RECOVER WASTE HEAT FROM EQUIPMENT $116,700 $90,000 Not Implemented
GT0815 # 02 Y:2005 02 2005 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT $84,900 $37,500 Not Implemented
GT0815 # 03 Y:2005 03 2005 ADJUST BURNERS FOR EFFICIENT OPERATION $62,800 $36,000 Not Implemented
GT0815 # 04 Y:2005 04 2005 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $40,800 $110,000 Not Implemented
GT0815 # 06 Y:2005 06 2005 USE SYNTHETIC LUBRICANT $4,865 $0 Implemented
GT0815 # 07 Y:2005 07 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $38,800 $12,500 Implemented
GT0815 # 08 Y:2005 08 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $58,229 $69,592 Implemented
GT0815 # 09 Y:2005 09 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,456 $39,000 Implemented
GT0815 # 05 Y:2005 05 2005 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $4,041 $1,500 Not Implemented
GT0756 # 15 Y:2003 15 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,065 $0 n/a
GT0756 # 12 Y:2003 12 2003 INSULATE BARE EQUIPMENT $1,474 $1,730 n/a
GT0756 # 11 Y:2003 11 2003 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $3,820 $0 n/a
GT0756 # 10 Y:2003 10 2003 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $5,098 $10,980 n/a
GT0756 # 09 Y:2003 09 2003 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $784 $0 n/a
GT0756 # 08 Y:2003 08 2003 REPLACE ELECTRIC MOTOR WITH FOSSIL FUEL ENGINE $89,400 $200,000 n/a
GT0756 # 07 Y:2003 07 2003 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS $56,040 $1,500 n/a
GT0756 # 06 Y:2003 06 2003 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $2,680 $1,850 n/a
GT0756 # 05 Y:2003 05 2003 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $10,000 $35,955 n/a
GT0756 # 04 Y:2003 04 2003 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $2,950 $1,620 n/a
GT0756 # 03 Y:2003 03 2003 ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF $22,800 $5,610 n/a
GT0756 # 02 Y:2003 02 2003 COVER OPEN TANKS $18,300 $3,000 n/a