IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,439

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0204 # 05 Y:1983 05 1983 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $19,377 $18,463 Not Implemented
GT0204 # 06 Y:1983 06 1983 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $8,630 $5,999 Not Implemented
GT0205 # 01 Y:1983 01 1983 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $55,852 $75,000 Not Implemented
GT0205 # 02 Y:1983 02 1983 MODIFY TEXTILE DRYERS $28,720 $50,000 Not Implemented
GT0205 # 03 Y:1983 03 1983 BURN WOOD BY-PRODUCTS FOR HEAT $274,827 $430,000 Not Implemented
GT0205 # 04 Y:1983 04 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,063 $1,850 Not Implemented
GT0193 # 01 Y:1983 01 1983 MODIFY TEXTILE DRYERS $159,000 $60,000 Not Implemented
GT0193 # 02 Y:1983 02 1983 CONTROL PRESSURE ON STEAMER OPERATIONS $13,000 $4,500 Not Implemented
GT0193 # 03 Y:1983 03 1983 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $8,300 $5,000 Not Implemented
GT0193 # 04 Y:1983 04 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,700 $500 Not Implemented
GT0193 # 05 Y:1983 05 1983 REPAIR AND ELIMINATE STEAM LEAKS $10,600 $900 Not Implemented
GT0193 # 06 Y:1983 06 1983 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $13,000 $3,100 Not Implemented
GT0193 # 07 Y:1983 07 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,163 $4,085 Not Implemented
GT0193 # 08 Y:1983 08 1983 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $8,300 $40,392 Not Implemented
GT0194 # 01 Y:1983 01 1983 INSTALL TIMERS AND/OR THERMOSTATS $630 $1,500 Implemented
GT0194 # 02 Y:1983 02 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $355 $570 Implemented
GT0194 # 03 Y:1983 03 1983 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $240 $0 Implemented
GT0196 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,239 $1,310 Not Implemented
GT0196 # 02 Y:1983 02 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,560 $4,880 Not Implemented
GT0196 # 03 Y:1983 03 1983 USE DEMAND CONTROLLER OR LOAD SHEDDER $9,340 $9,000 Not Implemented
GT0196 # 04 Y:1983 04 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $3,300 $6,000 Not Implemented
GT0196 # 05 Y:1983 05 1983 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,130 $1,000 Not Implemented
GT0196 # 06 Y:1983 06 1983 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $9,421 $12,000 Implemented
GT0196 # 07 Y:1983 07 1983 INSULATE BARE EQUIPMENT $2,850 $4,500 Not Implemented
GT0197 # 01 Y:1983 01 1983 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $20,601 $6,500 Not Implemented