Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

206

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0685 # 03 Y:2000 03 2000 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $714 $500 Implemented
GT0685 # 04 Y:2000 04 2000 UPGRADE CONTROLS ON COMPRESSORS $28,840 $7,000 Implemented
GT0685 # 05 Y:2000 05 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $15,955 $0 Implemented
GT0685 # 06 Y:2000 06 2000 $93,536 $30,000 Not Implemented
GT0685 # 07 Y:2000 07 2000 $144,500 $150,000 Not Implemented
GT0685 # 08 Y:2000 08 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $14,950 $4,740 Not Implemented
GT0684 # 01 Y:2000 01 2000 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $5,160 $0 Not Implemented
GT0684 # 02 Y:2000 02 2000 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $1,325 $0 Not Implemented
GT0684 # 03 Y:2000 03 2000 USE POWER DURING OFF-PEAK PERIODS $1,975 $0 Not Implemented
GT0684 # 04 Y:2000 04 2000 CLOSE OUTDOOR AIR DAMPERS DURING WARM-UP / COOL-DOWN PERIODS $1,632 $2,450 Not Implemented
GT0684 # 05 Y:2000 05 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,200 $19,600 Not Implemented
GT0683 # 01 Y:2000 01 2000 COMBINE UTILITY METERS $14,609 $0 Not Implemented
GT0683 # 02 Y:2000 02 2000 RECOVER WASTE HEAT FROM EQUIPMENT $180,287 $358,400 Not Implemented
GT0683 # 03 Y:2000 03 2000 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,689 $2,080 Not Implemented
GT0683 # 04 Y:2000 04 2000 $59,893 $12,000 Not Implemented
GT0683 # 05 Y:2000 05 2000 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,590 $108,696 Not Implemented
GT0683 # 06 Y:2000 06 2000 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $5,364 $11,500 Implemented
GT0683 # 07 Y:2000 07 2000 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $595 $1,275 Not Implemented
GT0683 # 08 Y:2000 08 2000 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $43,775 $28,880 Not Implemented
GT0683 # 09 Y:2000 09 2000 REUSE / RECYCLE/ SELL PAPER PRODUCTS $2,190 $1,000 Implemented
GT0682 # 01 Y:2000 01 2000 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $48,133 $1,000 Not Implemented
GT0682 # 02 Y:2000 02 2000 $36,150 $145,000 Not Implemented
GT0682 # 03 Y:2000 03 2000 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $16,620 $10,500 Implemented
GT0682 # 04 Y:2000 04 2000 RECOVER WASTE HEAT FROM EQUIPMENT $12,474 $45,900 Not Implemented
GT0682 # 05 Y:2000 05 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,829 $300 Not Implemented