IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

41

matching recommendations
Reset
SIC 265 Paperboard Containers And Boxes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0278 # 07 Y:1996 07 1996 TURN OFF EQUIPMENT WHEN NOT IN USE $5,818 $0 Implemented
WI0278 # 13 Y:1996 13 1996 MINIMIZE WATER USAGE $1,424 $0 Implemented
WI0278 # 12 Y:1996 12 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,899 $740 Implemented
WI0278 # 06 Y:1996 06 1996 MINIMIZE WATER USAGE $5,933 $1,000 Implemented
WI0278 # 05 Y:1996 05 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,241 $1,786 Not Implemented
WI0278 # 10 Y:1996 10 1996 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $4,441 $8,360 Not Implemented
WI0278 # 09 Y:1996 09 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $546 $0 Implemented
WI0278 # 08 Y:1996 08 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $976 $505 Not Implemented
WI0278 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,105 $11,072 Not Implemented
WI0278 # 03 Y:1996 03 1996 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $11,230 $500 Implemented
WI0278 # 02 Y:1996 02 1996 INSTALL SET-BACK TIMERS $15,919 $2,400 Implemented
WI0278 # 01 Y:1996 01 1996 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $141,768 $412,500 Not Implemented
WI0278 # 11 Y:1996 11 1996 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,999 $10,000 Implemented
WI0277 # 05 Y:1996 05 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,538 $1,642 Not Implemented
WI0277 # 10 Y:1996 10 1996 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $248 $700 Not Implemented
WI0277 # 09 Y:1996 09 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,309 $1,849 Not Implemented
WI0277 # 08 Y:1996 08 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,453 $500 Implemented
WI0277 # 07 Y:1996 07 1996 INSTALL AUTOMATIC STACK DAMPER $1,948 $3,000 Not Implemented
WI0277 # 06 Y:1996 06 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,245 $640 Not Implemented
WI0277 # 04 Y:1996 04 1996 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $4,365 $9,500 Implemented
WI0277 # 03 Y:1996 03 1996 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $5,800 $0 Not Implemented
WI0277 # 02 Y:1996 02 1996 INSTALL TIMERS AND/OR THERMOSTATS $6,122 $1,600 Not Implemented
WI0277 # 01 Y:1996 01 1996 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $18,642 $10,000 Not Implemented
WI0267 # 01 Y:1996 01 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $27,762 $8,906 n/a
WI0267 # 09 Y:1996 09 1996 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $2,236 $5,000 n/a