Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
433
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0269 # 07 Y:2004 | 07 | 2004 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $1,363 | $340 | Implemented |
BD0269 # 06 Y:2004 | 06 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,736 | $0 | Implemented |
BD0269 # 05 Y:2004 | 05 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,779 | $42 | Not Implemented |
BD0269 # 04 Y:2004 | 04 | 2004 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $2,160 | $5,500 | Implemented |
BD0269 # 03 Y:2004 | 03 | 2004 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $2,822 | $1,400 | Implemented |
BD0269 # 02 Y:2004 | 02 | 2004 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $3,568 | $3,200 | Implemented |
BD0269 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,588 | $225 | Implemented |
BD0267 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $234 | $210 | Implemented |
BD0267 # 01 Y:2004 | 01 | 2004 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $14,742 | $10,000 | Not Implemented |
BD0267 # 02 Y:2004 | 02 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,548 | $320 | Not Implemented |
BD0267 # 03 Y:2004 | 03 | 2004 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $3,575 | $3,000 | Not Implemented |
BD0267 # 04 Y:2004 | 04 | 2004 | USE RADIANT HEATER FOR SPOT HEATING | $2,983 | $4,250 | Not Implemented |
BD0267 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $818 | $60 | Implemented |
BD0267 # 06 Y:2004 | 06 | 2004 | INSTALL OCCUPANCY SENSORS | $749 | $720 | Implemented |
BD0267 # 07 Y:2004 | 07 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $364 | $0 | Implemented |
BD0267 # 09 Y:2004 | 09 | 2004 | USE PHOTOCELL CONTROLS | $229 | $250 | Not Implemented |
BD0267 # 10 Y:2004 | 10 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $173 | $292 | Implemented |
BD0267 # 11 Y:2004 | 11 | 2004 | USE SYNTHETIC LUBRICANT | $124 | $30 | Implemented |
BD0267 # 12 Y:2004 | 12 | 2004 | CONVERT TO ELECTROSTATIC POWDER COATING | $11,120 | $5,174 | Implemented |
BD0267 # 13 Y:2004 | 13 | 2004 | $9,750 | $2,500 | Not Implemented | |
IC0085 # 01 Y:2004 | 01 | 2004 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $25,215 | $2,944 | Implemented |
IC0085 # 02 Y:2004 | 02 | 2004 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,699 | $0 | Implemented |
IC0085 # 03 Y:2004 | 03 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,310 | $588 | Implemented |
IC0085 # 04 Y:2004 | 04 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $2,624 | $456 | Not Implemented |
IC0085 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $36,746 | $18,000 | Implemented |