IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

190

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IC0157 # 09 Y:2009 09 2009 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,416 $210 Not Implemented
IC0157 # 10 Y:2009 10 2009 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $2,332 $0 Not Implemented
IC0157 # 11 Y:2009 11 2009 UTILIZE A LESS EXPENSIVE COOLING METHOD $162,607 $289,000 Implemented
IC0157 # 12 Y:2009 12 2009 DISCONNECT BALLASTS $4,133 $1,070 Implemented
BD0364 # 01 Y:2009 01 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $27,695 $55,216 Not Implemented
BD0364 # 02 Y:2009 02 2009 INSTALL OCCUPANCY SENSORS $2,782 $2,025 Not Implemented
BD0364 # 03 Y:2009 03 2009 RECOVER WASTE HEAT FROM EQUIPMENT $3,526 $1,000 Not Implemented
BD0364 # 04 Y:2009 04 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $327 $0 Not Implemented
BD0364 # 05 Y:2009 05 2009 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $118 $500 Not Implemented
BD0364 # 06 Y:2009 06 2009 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $193 $300 Not Implemented
BD0364 # 07 Y:2009 07 2009 USE RADIANT HEATER FOR SPOT HEATING $4,732 $8,000 Not Implemented
BD0364 # 08 Y:2009 08 2009 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $1,047 $800 Not Implemented
BD0364 # 09 Y:2009 09 2009 $418 $0 Not Implemented
BD0362 # 01 Y:2009 01 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,931 $36,000 Implemented
BD0362 # 02 Y:2009 02 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $398 $325 Implemented
BD0362 # 03 Y:2009 03 2009 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $701 $100 Implemented
BD0362 # 04 Y:2009 04 2009 USE SYNTHETIC LUBRICANT $1,202 $300 Implemented
BD0362 # 05 Y:2009 05 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,945 $2,900 Implemented
BD0362 # 06 Y:2009 06 2009 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,913 $3,300 Implemented
BD0362 # 07 Y:2009 07 2009 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $7,156 $60,000 Not Implemented
BD0362 # 08 Y:2009 08 2009 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $200 $0 Not Implemented
BD0362 # 09 Y:2009 09 2009 USE POWER DURING OFF-PEAK PERIODS $15,684 $2,000 Not Implemented
BD0362 # 10 Y:2009 10 2009 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $2,248 $520 Implemented
BD0360 # 01 Y:2009 01 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,208 $20,180 Implemented
BD0360 # 02 Y:2009 02 2009 INSTALL OCCUPANCY SENSORS $1,709 $525 Not Implemented