Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
31
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TS0004 # 07 Y:1984 | 07 | 1984 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $10,352 | $25,218 | Not Implemented |
TS0004 # 06 Y:1984 | 06 | 1984 | INSTALL SET-BACK TIMERS | $5,296 | $0 | Not Implemented |
TS0004 # 05 Y:1984 | 05 | 1984 | INSULATE BARE EQUIPMENT | $11,480 | $5,460 | Not Implemented |
TS0004 # 04 Y:1984 | 04 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $15,174 | $42,000 | Not Implemented |
TS0004 # 03 Y:1984 | 03 | 1984 | INSULATE BARE EQUIPMENT | $396 | $33 | Not Implemented |
TS0004 # 02 Y:1984 | 02 | 1984 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $11,748 | $0 | Not Implemented |
TS0004 # 01 Y:1984 | 01 | 1984 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,158 | $1,360 | Not Implemented |
TS0011 # 02 Y:1984 | 02 | 1984 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $246 | $0 | Not Implemented |
TS0011 # 05 Y:1984 | 05 | 1984 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $217 | $0 | Not Implemented |
TS0011 # 01 Y:1984 | 01 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,244 | $500 | Not Implemented |
TS0011 # 03 Y:1984 | 03 | 1984 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $10,415 | $0 | Not Implemented |
TS0011 # 08 Y:1984 | 08 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $481 | $800 | Not Implemented |
TS0011 # 04 Y:1984 | 04 | 1984 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $677 | $2,376 | Not Implemented |
TS0011 # 06 Y:1984 | 06 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $242 | $500 | Not Implemented |
TS0007 # 01 Y:1984 | 01 | 1984 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $12,640 | $34,000 | Not Implemented |
TS0007 # 02 Y:1984 | 02 | 1984 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $13,248 | $25,350 | Not Implemented |
TS0007 # 03 Y:1984 | 03 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,860 | $0 | Implemented |
TS0007 # 05 Y:1984 | 05 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,243 | $0 | Implemented |
TS0003 # 04 Y:1984 | 04 | 1984 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $11,700 | $25,770 | Not Implemented |
TS0003 # 05 Y:1984 | 05 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,190 | $400 | Implemented |
TS0003 # 06 Y:1984 | 06 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,500 | $500 | Implemented |
TS0003 # 03 Y:1984 | 03 | 1984 | INSULATE BARE EQUIPMENT | $541 | $0 | Not Implemented |
TS0003 # 02 Y:1984 | 02 | 1984 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,050 | $1,400 | Implemented |
TS0003 # 01 Y:1984 | 01 | 1984 | MINIMIZE WATER USAGE | $3,197 | $6 | Implemented |
TS0002 # 01 Y:1984 | 01 | 1984 | INSTALL SET-BACK TIMERS | $2,178 | $0 | Implemented |