Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
30
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0817 # 02 Y:2010 | 02 | 2010 | OPTIMIZE PLANT POWER FACTOR | $63,586 | $41,250 | Not Implemented |
UD0817 # 14 Y:2010 | 14 | 2010 | RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION | $300 | $50 | Not Implemented |
UD0817 # 13 Y:2010 | 13 | 2010 | INSULATE BARE EQUIPMENT | $21,893 | $0 | Implemented |
UD0817 # 12 Y:2010 | 12 | 2010 | COVER OPEN TANKS | $10,386 | $0 | Implemented |
UD0817 # 11 Y:2010 | 11 | 2010 | USE OPTIMUM TEMPERATURE | $8,137 | $0 | Implemented |
UD0817 # 10 Y:2010 | 10 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,001 | $2,366 | Not Implemented |
UD0817 # 09 Y:2010 | 09 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,120 | $0 | Implemented |
UD0817 # 08 Y:2010 | 08 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,696 | $2,250 | Not Implemented |
UD0817 # 07 Y:2010 | 07 | 2010 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $628 | $0 | Implemented |
UD0817 # 06 Y:2010 | 06 | 2010 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,712 | $7,628 | Not Implemented |
UD0817 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,546 | $3,000 | Not Implemented |
UD0817 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,364 | $1,876 | Not Implemented |
UD0817 # 03 Y:2010 | 03 | 2010 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $9,387 | $0 | Not Implemented |
UD0817 # 18 Y:2010 | 18 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,624 | $5,686 | Not Implemented |
UD0817 # 01 Y:2010 | 01 | 2010 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $66,672 | $600 | Implemented |
UD0817 # 15 Y:2010 | 15 | 2010 | INSULATE BARE EQUIPMENT | $3,996 | $0 | Implemented |
UD0817 # 16 Y:2010 | 16 | 2010 | REDESIGN PROCESS | $357,330 | $0 | Not Implemented |
UD0817 # 17 Y:2010 | 17 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $18,312 | $36,624 | Not Implemented |
UD0814 # 11 Y:2010 | 11 | 2010 | INSULATE BARE EQUIPMENT | $1,111 | $807 | Not Implemented |
UD0814 # 09 Y:2010 | 09 | 2010 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $8,568 | $3,000 | Implemented |
UD0814 # 08 Y:2010 | 08 | 2010 | INSULATE BARE EQUIPMENT | $18,417 | $9,030 | Not Implemented |
UD0814 # 06 Y:2010 | 06 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,642 | $1,000 | Implemented |
UD0814 # 05 Y:2010 | 05 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $386 | $0 | Implemented |
UD0814 # 04 Y:2010 | 04 | 2010 | DEVELOP A REPAIR/REPLACE POLICY | $899 | $1,724 | Implemented |
UD0814 # 03 Y:2010 | 03 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,684 | $21,115 | Not Implemented |