Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

260

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0119 # 07 Y:1984 07 1984 OPERATE BOILERS ON HIGH FIRE SETTING $2,034 $50 Implemented
KU0119 # 08 Y:1984 08 1984 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $1,240 $0 Implemented
KU0119 # 09 Y:1984 09 1984 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $982 $200 Implemented
KU0119 # 12 Y:1984 12 1984 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $393 $50 Implemented
KU0119 # 14 Y:1984 14 1984 INSULATE BARE EQUIPMENT $264 $150 Implemented
KU0089 # 01 Y:1983 01 1983 RECOVER WASTE HEAT FROM EQUIPMENT $7,499 $24,000 Implemented
KU0089 # 02 Y:1983 02 1983 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $7,163 $100 Implemented
KU0089 # 03 Y:1983 03 1983 INSTALL TIMERS AND/OR THERMOSTATS $2,999 $200 Implemented
KU0089 # 04 Y:1983 04 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $4,058 $2,580 Implemented
KU0089 # 05 Y:1983 05 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,992 $2,970 Implemented
KU0089 # 06 Y:1983 06 1983 INCREASE AMOUNT OF CONDENSATE RETURNED $1,182 $1,044 Implemented
KU0089 # 07 Y:1983 07 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $322 $550 Implemented
KU0089 # 08 Y:1983 08 1983 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $182 $0 Implemented
KU0089 # 09 Y:1983 09 1983 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $117 $170 Implemented
KU0085 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,553 $21,306 Implemented
KU0085 # 02 Y:1983 02 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $14,849 $9,478 Implemented
KU0085 # 03 Y:1983 03 1983 INSTALL TIMERS AND/OR THERMOSTATS $7,806 $4,800 Implemented
KU0085 # 04 Y:1983 04 1983 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $13,011 $11,400 Implemented
KU0085 # 05 Y:1983 05 1983 INSTALL / REPAIR INSULATION ON STEAM LINES $105,477 $25,000 Implemented
KU0085 # 06 Y:1983 06 1983 INSULATE BARE EQUIPMENT $2,958 $4,861 Implemented
KU0085 # 07 Y:1983 07 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $51,359 $2,500 Implemented
KU0065 # 03 Y:1982 03 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,815 $0 Implemented
KU0056 # 01 Y:1982 01 1982 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $10,692 $2,784 Implemented
KU0056 # 02 Y:1982 02 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $17,863 $2,000 Implemented
KU0056 # 03 Y:1982 03 1982 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $16,065 $20,000 Implemented