IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

30

matching recommendations
Reset
SIC 30 Rubber And Miscellaneous Plastics Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0060 # 04 Y:1982 04 1982 INSTALL TIMERS AND/OR THERMOSTATS $1,874 $600 Not Implemented
KU0060 # 03 Y:1982 03 1982 OPTIMIZE PLANT POWER FACTOR $4,740 $1,940 Implemented
KU0060 # 02 Y:1982 02 1982 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $246 $304 Not Implemented
KU0060 # 01 Y:1982 01 1982 RECOVER WASTE HEAT FROM EQUIPMENT $4,789 $5,000 Not Implemented
KU0060 # 05 Y:1982 05 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,110 $3,248 Not Implemented
KU0060 # 06 Y:1982 06 1982 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,469 $1,543 Not Implemented
KU0060 # 07 Y:1982 07 1982 LOWER CEILING TO REDUCE CONDITIONED SPACE $792 $500 Not Implemented
KU0060 # 08 Y:1982 08 1982 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $4,812 $7,480 Not Implemented
KU0054 # 01 Y:1982 01 1982 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $133,013 $240,000 Not Implemented
KU0054 # 02 Y:1982 02 1982 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $27,871 $0 Not Implemented
KU0054 # 03 Y:1982 03 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,358 $11,910 Implemented
KU0054 # 04 Y:1982 04 1982 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $5,428 $5,000 Not Implemented
KU0054 # 05 Y:1982 05 1982 USE OPTIMUM THICKNESS INSULATION $1,888 $880 Implemented
KU0054 # 06 Y:1982 06 1982 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $1,360 $0 Not Implemented
KU0043 # 02 Y:1982 02 1982 INSTALL TIMERS AND/OR THERMOSTATS $4,890 $4,800 Not Implemented
KU0043 # 06 Y:1982 06 1982 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $3,332 $818 Not Implemented
KU0043 # 05 Y:1982 05 1982 USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS $20,364 $40,000 Not Implemented
KU0043 # 04 Y:1982 04 1982 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $162,065 $20,000 Not Implemented
KU0043 # 03 Y:1982 03 1982 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $8,989 $550 Not Implemented
KU0043 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,438 $2,000 Not Implemented
KU0031 # 03 Y:1982 03 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,083 $3,000 Not Implemented
KU0031 # 02 Y:1982 02 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,393 $725 Not Implemented
KU0032 # 01 Y:1982 01 1982 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $14,570 $0 Not Implemented
KU0032 # 02 Y:1982 02 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,434 $0 Not Implemented
KU0032 # 03 Y:1982 03 1982 INSULATE BARE EQUIPMENT $3,756 $475 Not Implemented