IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

226

matching recommendations
Reset
SIC 35 Industrial Machinery And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0476 # 01 Y:1997 01 1997 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $13,340 $0 Implemented
KU0476 # 03 Y:1997 03 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,360 $5,470 Implemented
KU0476 # 04 Y:1997 04 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,010 $230 Implemented
KU0476 # 10 Y:1997 10 1997 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $3,340 $300 Implemented
KU0476 # 11 Y:1997 11 1997 $7,620 $0 Implemented
KU0476 # 08 Y:1997 08 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $180 $270 Implemented
KU0474 # 07 Y:1997 07 1997 INSTALL OCCUPANCY SENSORS $140 $800 Implemented
KU0474 # 05 Y:1997 05 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,350 $4,950 Implemented
KU0474 # 04 Y:1997 04 1997 ADJUST BURNERS FOR EFFICIENT OPERATION $660 $1,000 Implemented
KU0474 # 03 Y:1997 03 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,270 $190 Implemented
KU0474 # 02 Y:1997 02 1997 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,490 $6,950 Implemented
KU0474 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,680 $27,070 Implemented
KU0473 # 05 Y:1997 05 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $200 $360 Implemented
KU0473 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,020 $3,480 Implemented
KU0473 # 03 Y:1997 03 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $220 $100 Implemented
KU0473 # 06 Y:1997 06 1997 REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS $390 $110 Implemented
KU0473 # 04 Y:1997 04 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $230 $450 Implemented
KU0466 # 01 Y:1996 01 1996 USE RADIANT HEATER FOR SPOT HEATING $23,445 $31,940 Implemented
KU0466 # 02 Y:1996 02 1996 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $16,546 $12,960 Implemented
KU0466 # 04 Y:1996 04 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,223 $302 Implemented
KU0466 # 06 Y:1996 06 1996 INSULATE BARE EQUIPMENT $1,182 $139 Implemented
KU0466 # 09 Y:1996 09 1996 USE SYNTHETIC LUBRICANT $418 $105 Implemented
KU0466 # 11 Y:1996 11 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $135 $119 Implemented
KU0466 # 10 Y:1996 10 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $387 $688 Implemented
KU0466 # 07 Y:1996 07 1996 INSTALL OCCUPANCY SENSORS $731 $700 Implemented