Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
91
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UL0104 # 04 Y:1994 | 04 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,884 | $13,940 | n/a |
UL0104 # 05 Y:1994 | 05 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,476 | $4,575 | n/a |
UD0433 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,315 | $1,950 | Implemented |
UD0433 # 04 Y:1994 | 04 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,093 | $2,500 | Not Implemented |
UD0433 # 03 Y:1994 | 03 | 1994 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $2,059 | $300 | Implemented |
UD0433 # 02 Y:1994 | 02 | 1994 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $4,410 | $0 | Implemented |
UD0433 # 01 Y:1994 | 01 | 1994 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $6,342 | $20,000 | Not Implemented |
UL0101 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,975 | $8,590 | n/a |
UL0101 # 07 Y:1994 | 07 | 1994 | LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE | $3,085 | $1,000 | n/a |
UL0101 # 06 Y:1994 | 06 | 1994 | INSULATE BARE EQUIPMENT | $791 | $588 | n/a |
UL0101 # 05 Y:1994 | 05 | 1994 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $3,325 | $10,000 | n/a |
UL0101 # 04 Y:1994 | 04 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $420 | $150 | n/a |
UL0101 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,055 | $3,163 | n/a |
UL0101 # 02 Y:1994 | 02 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,444 | $696 | n/a |
UL0101 # 08 Y:1994 | 08 | 1994 | INSULATE BARE EQUIPMENT | $463 | $558 | n/a |
TN0533 # 03 Y:1994 | 03 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,344 | $1,680 | Not Implemented |
TN0533 # 01 Y:1994 | 01 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,262 | $4,455 | Not Implemented |
TN0533 # 02 Y:1994 | 02 | 1994 | INSULATE BARE EQUIPMENT | $4,449 | $200 | Implemented |
TN0533 # 04 Y:1994 | 04 | 1994 | INSTALL TIMERS AND/OR THERMOSTATS | $1,318 | $700 | Implemented |
TN0533 # 05 Y:1994 | 05 | 1994 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,300 | $0 | Not Implemented |
TN0533 # 06 Y:1994 | 06 | 1994 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,523 | $3,350 | Implemented |
TN0533 # 08 Y:1994 | 08 | 1994 | MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT | $34,098 | $45,100 | Implemented |
TN0533 # 09 Y:1994 | 09 | 1994 | IMPROVED MATERIAL HANDLING (MIXING AND TRANSFER) | $18,473 | $5,000 | Not Implemented |
TN0533 # 10 Y:1994 | 10 | 1994 | TREAT AND REUSE RINSE WATERS | $7,445 | $12,650 | Not Implemented |
TN0533 # 11 Y:1994 | 11 | 1994 | CONVERT TO AQUEOUS CLEANING SYSTEM | $3,325 | $3,000 | Implemented |