Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
122
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UL0229 # 02 Y:1999 | 02 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $8,274 | $469 | Implemented |
UL0236 # 03 Y:1999 | 03 | 1999 | $48,322 | $66,150 | Not Implemented | |
UL0236 # 02 Y:1999 | 02 | 1999 | WASH AND REUSE RAGS ON-SITE | $5,446 | $11,315 | Not Implemented |
UL0236 # 01 Y:1999 | 01 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,472 | $20 | Implemented |
UL0232 # 03 Y:1999 | 03 | 1999 | RECOVER AND REUSE COOLING WATER | $56,903 | $5,370 | Implemented |
UL0232 # 02 Y:1999 | 02 | 1999 | RECOVER AND REUSE COOLING WATER | $9,701 | $446 | Not Implemented |
UL0232 # 01 Y:1999 | 01 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,709 | $100 | Not Implemented |
UL0226 # 02 Y:1999 | 02 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,020 | $522 | Implemented |
UL0226 # 01 Y:1999 | 01 | 1999 | OPTIMIZE PLANT POWER FACTOR | $92,078 | $100,203 | Not Implemented |
UL0226 # 04 Y:1999 | 04 | 1999 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $433 | $930 | Implemented |
UL0226 # 03 Y:1999 | 03 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $15,134 | $0 | Implemented |
TN0670 # 07 Y:1999 | 07 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $335 | $0 | Implemented |
TN0670 # 06 Y:1999 | 06 | 1999 | USE SYNTHETIC LUBRICANT | $342 | $0 | Not Implemented |
TN0670 # 05 Y:1999 | 05 | 1999 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $493 | $625 | Not Implemented |
TN0670 # 04 Y:1999 | 04 | 1999 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $640 | $1,250 | Implemented |
TN0670 # 03 Y:1999 | 03 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $6,283 | $3,000 | Implemented |
TN0670 # 02 Y:1999 | 02 | 1999 | $20,663 | $16,000 | Not Implemented | |
TN0670 # 01 Y:1999 | 01 | 1999 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $30,906 | $3,200 | Implemented |
UL0231 # 03 Y:1999 | 03 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $876 | $0 | Not Implemented |
UL0231 # 04 Y:1999 | 04 | 1999 | $36,750 | $23,166 | Not Implemented | |
UL0231 # 02 Y:1999 | 02 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $757 | $0 | Not Implemented |
UL0231 # 01 Y:1999 | 01 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,275 | $101 | Not Implemented |
UL0227 # 01 Y:1999 | 01 | 1999 | RECOVER AND REUSE WASTE MATERIAL | $43,200 | $5,000 | Not Implemented |
UL0227 # 02 Y:1999 | 02 | 1999 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $48,094 | $8,165 | Not Implemented |
UL0227 # 04 Y:1999 | 04 | 1999 | $318,710 | $533,131 | Not Implemented |