IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

198

matching recommendations
Reset
SIC 3089 Plastics Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ND0309 # 02 Y:1998 02 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,616 $17,376 Implemented
ND0309 # 03 Y:1998 03 1998 RECOVER AND REUSE WASTE MATERIAL $3,750 $125 Not Implemented
ND0309 # 04 Y:1998 04 1998 $1,604 $2,500 Not Implemented
ND0309 # 05 Y:1998 05 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,366 $1,000 Not Implemented
ND0309 # 06 Y:1998 06 1998 CONVERT TO AQUEOUS CLEANING SYSTEM $848 $100 Implemented
ND0309 # 07 Y:1998 07 1998 $478 $0 Implemented
ND0309 # 08 Y:1998 08 1998 INSTALL OCCUPANCY SENSORS $458 $800 Not Implemented
ND0309 # 09 Y:1998 09 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $131 $60 Implemented
ND0309 # 10 Y:1998 10 1998 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $101 $250 Not Implemented
ND0309 # 11 Y:1998 11 1998 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $20 $20 Implemented
UM0091 # 01 Y:1997 01 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,010 $1,307 Not Implemented
UM0091 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,671 $12,962 Not Implemented
UM0091 # 03 Y:1997 03 1997 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $3,775 $90 Not Implemented
UM0091 # 04 Y:1997 04 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $624 $600 Not Implemented
UM0091 # 05 Y:1997 05 1997 $90,870 $30,000 Not Implemented
UM0045 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,377 $730 Not Implemented
UM0045 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,728 $18,135 Not Implemented
UM0045 # 03 Y:1995 03 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,355 $1,000 Not Implemented
UM0045 # 04 Y:1995 04 1995 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $4,611 $500 Implemented
UM0045 # 05 Y:1995 05 1995 OPTIMIZE PLANT POWER FACTOR $9,291 $14,954 Not Implemented
ND0229 # 01 Y:1995 01 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,253 $1,120 Implemented
ND0229 # 02 Y:1995 02 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,160 $6,280 Implemented
ND0229 # 03 Y:1995 03 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,594 $300 Not Implemented
ND0229 # 04 Y:1995 04 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $567 $358 Implemented
ND0229 # 05 Y:1995 05 1995 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $8,900 $15,020 Implemented