Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
36
matching recommendationsSIC | 22 | Textile Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0499 # 13 Y:2013 | 13 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,510 | $100 | Implemented |
NC0499 # 04 Y:2013 | 04 | 2013 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $10,670 | $35,000 | Not Implemented |
NC0499 # 03 Y:2013 | 03 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $11,043 | $0 | Not Implemented |
NC0499 # 02 Y:2013 | 02 | 2013 | OPERATE BOILERS ON HIGH FIRE SETTING | $17,607 | $1,000 | Implemented |
NC0499 # 01 Y:2013 | 01 | 2013 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $52,036 | $15,000 | Implemented |
NC0499 # 05 Y:2013 | 05 | 2013 | INSULATE BARE EQUIPMENT | $3,164 | $1,617 | Not Implemented |
NC0499 # 06 Y:2013 | 06 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,539 | $1,165 | Not Implemented |
NC0499 # 10 Y:2013 | 10 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,040 | $12,800 | Implemented |
NC0499 # 12 Y:2013 | 12 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,194 | $451 | Implemented |
NC0499 # 11 Y:2013 | 11 | 2013 | INSTALL OCCUPANCY SENSORS | $3,113 | $3,202 | Not Implemented |
NC0499 # 07 Y:2013 | 07 | 2013 | REPAIR AND ELIMINATE STEAM LEAKS | $1,306 | $1,750 | Implemented |
NC0499 # 08 Y:2013 | 08 | 2013 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $5,104 | $200 | Not Implemented |
NC0499 # 09 Y:2013 | 09 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,448 | $18,119 | Implemented |
NC0499 # 14 Y:2013 | 14 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $2,055 | $4,256 | Implemented |
NC0493 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,789 | $215,791 | Implemented |
NC0493 # 13 Y:2013 | 13 | 2013 | CONDENSE OPERATION INTO ONE BUILDING | $21,473 | $10,000 | Implemented |
NC0493 # 12 Y:2013 | 12 | 2013 | TREAT AND REUSE RINSE WATERS | $28,586 | $90,000 | Not Implemented |
NC0493 # 11 Y:2013 | 11 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,410 | $15,000 | Not Implemented |
NC0493 # 09 Y:2013 | 09 | 2013 | REDUCE EXCESSIVE BOILER BLOWDOWN | $430 | $0 | Implemented |
NC0493 # 08 Y:2013 | 08 | 2013 | INCREASE AMOUNT OF CONDENSATE RETURNED | $13,410 | $10,000 | Not Implemented |
NC0493 # 07 Y:2013 | 07 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $853 | $1,447 | Not Implemented |
NC0493 # 06 Y:2013 | 06 | 2013 | INSULATE BARE EQUIPMENT | $15,385 | $1,820 | Not Implemented |
NC0493 # 05 Y:2013 | 05 | 2013 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $37,850 | $6,372 | Implemented |
NC0493 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,550 | $1,386 | Implemented |
NC0493 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $3,826 | $7,934 | Not Implemented |