Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
88
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0370 # 02 Y:2007 | 02 | 2007 | REPAIR OR REPLACE STEAM TRAPS | $43,809 | $17,100 | Not Implemented |
NC0370 # 06 Y:2007 | 06 | 2007 | MINIMIZE WATER USAGE | $74,891 | $121,780 | Not Implemented |
NC0370 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $48,768 | $120,500 | Not Implemented |
NC0370 # 04 Y:2007 | 04 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $27,567 | $74,816 | Not Implemented |
NC0370 # 03 Y:2007 | 03 | 2007 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $48,420 | $25,000 | Not Implemented |
NC0370 # 05 Y:2007 | 05 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $45,052 | $88,200 | Not Implemented |
NC0370 # 09 Y:2007 | 09 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,690 | $50 | Not Implemented |
NC0370 # 01 Y:2007 | 01 | 2007 | ADJUST BURNERS FOR EFFICIENT OPERATION | $30,975 | $65,000 | Not Implemented |
NC0370 # 10 Y:2007 | 10 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,644 | $7,240 | Not Implemented |
NC0370 # 07 Y:2007 | 07 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $87,257 | $136,000 | Not Implemented |
NC0369 # 09 Y:2007 | 09 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $694 | $1,564 | Not Implemented |
NC0369 # 05 Y:2007 | 05 | 2007 | KEEP BOILER TUBES CLEAN | $2,955 | $1,000 | Implemented |
NC0369 # 06 Y:2007 | 06 | 2007 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,730 | $0 | Implemented |
NC0369 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,862 | $0 | Not Implemented |
NC0369 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,910 | $100 | Implemented |
NC0369 # 03 Y:2007 | 03 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,420 | $1,500 | Implemented |
NC0369 # 02 Y:2007 | 02 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,750 | $13,500 | Implemented |
NC0369 # 01 Y:2007 | 01 | 2007 | COVER OPEN TANKS | $11,745 | $2,500 | Not Implemented |
NC0369 # 07 Y:2007 | 07 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $968 | $2,159 | Not Implemented |
NC0368 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,986 | $100 | Implemented |
NC0368 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,394 | $3,917 | Not Implemented |
NC0368 # 02 Y:2007 | 02 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $640 | $1,297 | Implemented |
NC0368 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,919 | $50 | Implemented |
NC0368 # 01 Y:2007 | 01 | 2007 | BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT | $42,586 | $100,000 | Not Implemented |
NC0368 # 06 Y:2007 | 06 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $267 | $960 | Implemented |