Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

217

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0484 # 04 Y:2013 04 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,039 $1,124 Not Implemented
NC0484 # 05 Y:2013 05 2013 USE PHOTOCELL CONTROLS $2,065 $250 Implemented
NC0484 # 06 Y:2013 06 2013 RECOVER WASTE HEAT FROM EQUIPMENT $56,670 $60,000 Not Implemented
NC0484 # 07 Y:2013 07 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,306 $100 Implemented
NC0486 # 01 Y:2013 01 2013 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,365 $4,000 Implemented
NC0486 # 02 Y:2013 02 2013 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $150 $25 Implemented
NC0486 # 03 Y:2013 03 2013 INSTALL OCCUPANCY SENSORS $2,878 $4,661 Not Implemented
NC0486 # 04 Y:2013 04 2013 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $1,752 $4,400 Not Implemented
NC0478 # 01 Y:2013 01 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,457 $15,267 Not Implemented
NC0478 # 02 Y:2013 02 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $858 $2,621 Not Implemented
NC0478 # 03 Y:2013 03 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $649 $562 Not Implemented
NC0478 # 04 Y:2013 04 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $557 $1,410 Implemented
NC0478 # 05 Y:2013 05 2013 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $489 $0 Implemented
NC0478 # 06 Y:2013 06 2013 TURN OFF EQUIPMENT WHEN NOT IN USE $3,874 $1,800 Implemented
NC0478 # 07 Y:2013 07 2013 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,287 $2,015 Not Implemented
NC0478 # 08 Y:2013 08 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $219 $200 Implemented
NC0478 # 09 Y:2013 09 2013 DEVELOP A REPAIR/REPLACE POLICY $4,732 $10,912 Implemented
NC0483 # 01 Y:2013 01 2013 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $240,743 $750,000 Not Implemented
NC0483 # 02 Y:2013 02 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $18,552 $69,000 Not Implemented
NC0483 # 03 Y:2013 03 2013 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $8,715 $20,000 Not Implemented
NC0483 # 04 Y:2013 04 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $80,247 $134,713 Implemented
NC0483 # 05 Y:2013 05 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,537 $18,520 Implemented
NC0483 # 06 Y:2013 06 2013 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $791 $50 Implemented
NC0479 # 01 Y:2013 01 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $9,663 $40,000 Not Implemented
NC0479 # 02 Y:2013 02 2013 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $6,601 $10,000 Implemented