Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

131

matching recommendations
Reset
SIC 201 Meat Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0317 # 05 Y:2003 05 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $930 $408 Implemented
IA0317 # 06 Y:2003 06 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,527 $1,007 Implemented
IA0317 # 07 Y:2003 07 2003 CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS $8,984 $75,000 Implemented
IA0317 # 08 Y:2003 08 2003 $15,600 $18,500 Not Implemented
IA0316 # 01 Y:2003 01 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,140 $4,916 Implemented
IA0316 # 02 Y:2003 02 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $551 $64 Implemented
IA0316 # 03 Y:2003 03 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $367 $20 Implemented
IA0316 # 04 Y:2003 04 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $167 $14 Implemented
IA0316 # 05 Y:2003 05 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $6,380 $18,000 Not Implemented
IA0316 # 06 Y:2003 06 2003 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,330 $1,000 Implemented
IA0316 # 07 Y:2003 07 2003 DIRECT WARMEST AIR TO COMBUSTION INTAKE $528 $800 Implemented
IA0316 # 08 Y:2003 08 2003 INSTALL OCCUPANCY SENSORS $779 $1,530 n/a
IA0316 # 09 Y:2003 09 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $560 $560 n/a
IA0316 # 10 Y:2003 10 2003 INSTALL OCCUPANCY SENSORS $522 $860 n/a
IA0316 # 11 Y:2003 11 2003 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS $2,969 $5,770 n/a
IA0186 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,615 $8,935 Implemented
IA0186 # 02 Y:1997 02 1997 DIRECT WARMEST AIR TO COMBUSTION INTAKE $961 $1,344 Not Implemented
IA0186 # 03 Y:1997 03 1997 INSTALL OCCUPANCY SENSORS $535 $266 Not Implemented
IA0186 # 04 Y:1997 04 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $0 $0 Implemented
IA0186 # 05 Y:1997 05 1997 IMPROVED MATERIAL HANDLING (MIXING AND TRANSFER) $25,740 $1,061 Implemented
IA0186 # 06 Y:1997 06 1997 CONTRACT A WOOD PALLET RECYCLING COMPANY $10,267 $2,000 Implemented
IA0186 # 07 Y:1997 07 1997 MINIMIZE WATER USAGE $842 $375 Implemented
IA0186 # 08 Y:1997 08 1997 $90,000 $11,800 Implemented
IA0186 # 09 Y:1997 09 1997 $21,840 $30,000 Implemented
CO0372 # 01 Y:1996 01 1996 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $6,270 $13,320 Implemented