IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

55

matching recommendations
Reset
SIC 38 Instruments And Related Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NL0040 # 03 Y:2019 03 2019 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $25,402 $1,697 Implemented
NL0040 # 02 Y:2019 02 2019 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $38,925 $150,000 Not Implemented
NL0040 # 01 Y:2019 01 2019 OPTIMIZE PLANT POWER FACTOR $106,822 $130,000 Not Implemented
NL0008 # 04 Y:2017 04 2017 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $111 $0 Not Implemented
NL0008 # 03 Y:2017 03 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $457 $4,600 Implemented
NL0008 # 02 Y:2017 02 2017 INSTALL OCCUPANCY SENSORS $1,330 $14,200 Implemented
NL0008 # 01 Y:2017 01 2017 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,345 $0 Implemented
NL0006 # 05 Y:2017 05 2017 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $1,213 $0 Implemented
NL0006 # 04 Y:2017 04 2017 USE DEMAND CONTROLLER OR LOAD SHEDDER $4,082 $4,000 Implemented
NL0006 # 03 Y:2017 03 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,100 $0 Implemented
NL0006 # 02 Y:2017 02 2017 DISTILL CONTAMINATED SOLVENTS FOR REUSE $14,999 $22,000 Implemented
NL0006 # 01 Y:2017 01 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $25,351 $69,750 Implemented
IA0210 # 03 Y:1998 03 1998 INSTALL OCCUPANCY SENSORS $2,457 $2,793 Implemented
IA0210 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,138 $17,423 Implemented
IA0210 # 02 Y:1998 02 1998 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $4,040 $12,186 Not Implemented
IA0210 # 05 Y:1998 05 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $134 $282 Implemented
IA0210 # 07 Y:1998 07 1998 USE RADIANT HEATER FOR SPOT HEATING $2,824 $10,101 Not Implemented
IA0210 # 04 Y:1998 04 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,766 $4,820 Implemented
IA0210 # 06 Y:1998 06 1998 $261,385 $19,800 Not Implemented
KU0448 # 08 Y:1994 08 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $413 $720 Implemented
KU0448 # 07 Y:1994 07 1994 INSTALL OCCUPANCY SENSORS $2,094 $1,800 Not Implemented
KU0448 # 05 Y:1994 05 1994 INSULATE BARE EQUIPMENT $1,200 $2,295 Not Implemented
KU0448 # 04 Y:1994 04 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,612 $462 Implemented
KU0448 # 03 Y:1994 03 1994 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $7,469 $12,750 Not Implemented
KU0448 # 02 Y:1994 02 1994 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $11,016 $10,390 Not Implemented