IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

102

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0382 # 01 Y:2014 01 2014 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $11,599 $0 Implemented
LE0382 # 05 Y:2014 05 2014 INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS $2,534 $4,030 Not Implemented
LE0382 # 06 Y:2014 06 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $792 $2,500 Not Implemented
LE0382 # 03 Y:2014 03 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,119 $0 Implemented
LE0382 # 07 Y:2014 07 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,433 $8,016 Implemented
LE0382 # 04 Y:2014 04 2014 INSTALL TIMERS AND/OR THERMOSTATS $1,431 $1,516 Not Implemented
LE0382 # 02 Y:2014 02 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $555 $0 Implemented
LE0380 # 04 Y:2014 04 2014 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $1,824 $2,960 Not Implemented
LE0380 # 02 Y:2014 02 2014 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,774 $800 Not Implemented
LE0380 # 01 Y:2014 01 2014 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $19,389 $780 Not Implemented
LE0380 # 06 Y:2014 06 2014 USE RADIANT HEATER FOR SPOT HEATING $22,320 $54,000 Not Implemented
LE0380 # 08 Y:2014 08 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,740 $4,950 Not Implemented
LE0380 # 07 Y:2014 07 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,916 $5,000 Not Implemented
LE0380 # 05 Y:2014 05 2014 RECOVER WASTE HEAT FROM EQUIPMENT $938 $1,936 Not Implemented
LE0380 # 03 Y:2014 03 2014 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $593 $520 Not Implemented
LE0380 # 09 Y:2014 09 2014 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $607 $2,000 Not Implemented
LE0385 # 04 Y:2014 04 2014 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $8,746 $11,000 Implemented
LE0385 # 06 Y:2014 06 2014 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $8,266 $13,200 Not Implemented
LE0385 # 02 Y:2014 02 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $38,455 $1,000 Implemented
LE0385 # 09 Y:2014 09 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,496 $12,000 Implemented
LE0385 # 05 Y:2014 05 2014 INSTALL OCCUPANCY SENSORS $7,685 $12,000 Implemented
LE0385 # 01 Y:2014 01 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $10,165 $40 Not Implemented
LE0385 # 11 Y:2014 11 2014 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $4,728 $11,400 Not Implemented
LE0385 # 08 Y:2014 08 2014 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,231 $4,000 Not Implemented
LE0385 # 07 Y:2014 07 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,022 $1,700 Implemented