Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
130
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0155 # 02 Y:2015 | 02 | 2015 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $500 | $0 | Implemented |
DL0155 # 03 Y:2015 | 03 | 2015 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $8,960 | $6,880 | Not Implemented |
DL0155 # 01 Y:2015 | 01 | 2015 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,690 | $0 | Implemented |
DL0155 # 04 Y:2015 | 04 | 2015 | SHADE WINDOWS FROM SUMMER SUN | $1,760 | $6,840 | Not Implemented |
DL0155 # 05 Y:2015 | 05 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,405 | $13,615 | Not Implemented |
DL0149 # 02 Y:2015 | 02 | 2015 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,780 | $0 | Implemented |
DL0149 # 11 Y:2015 | 11 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,290 | $29,215 | Not Implemented |
DL0149 # 10 Y:2015 | 10 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $480 | $1,200 | Implemented |
DL0149 # 09 Y:2015 | 09 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $600 | $3,200 | Implemented |
DL0149 # 08 Y:2015 | 08 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $470 | $1,430 | Implemented |
DL0149 # 07 Y:2015 | 07 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,930 | $7,440 | Implemented |
DL0149 # 06 Y:2015 | 06 | 2015 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $870 | $50 | Implemented |
DL0149 # 03 Y:2015 | 03 | 2015 | INSTALL TIMERS AND/OR THERMOSTATS | $6,060 | $35 | Implemented |
DL0149 # 01 Y:2015 | 01 | 2015 | INSULATE BARE EQUIPMENT | $15,210 | $630 | Not Implemented |
DL0149 # 04 Y:2015 | 04 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,900 | $1,250 | Not Implemented |
DL0149 # 05 Y:2015 | 05 | 2015 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $1,140 | $40 | Implemented |
LE0400 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,673 | $1,000 | Implemented |
LE0400 # 06 Y:2015 | 06 | 2015 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $27,922 | $10,500 | Not Implemented |
LE0400 # 01 Y:2015 | 01 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $16,723 | $28 | Implemented |
LE0400 # 09 Y:2015 | 09 | 2015 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $9,334 | $16,500 | Implemented |
LE0400 # 05 Y:2015 | 05 | 2015 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $30,027 | $5,000 | Not Implemented |
LE0400 # 07 Y:2015 | 07 | 2015 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,457 | $3,025 | Implemented |
LE0400 # 04 Y:2015 | 04 | 2015 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $8,953 | $1,920 | Not Implemented |
LE0400 # 02 Y:2015 | 02 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,648 | $512 | Implemented |
LE0400 # 08 Y:2015 | 08 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $26,074 | $35,000 | Not Implemented |